Model UV232A-4S and UV232A-8S

8

2.6 Cable Requirements

All units can use with CAT5/5e/6 or Zero-Skew™ UTP or STP (unshielded or
shielded twisted pair) cables.

All units provide high-frequency compensation (to account for the losses in the CATx
cable). The URA-232 and URA-232-XT units also provide RGB skew correction.

2.7 Daisy-Chain Limitations

The Model URA-232-XT allows downstream receiver units to be daisy chained using
UTP cables. This eliminates the need for running separate cables from every
receiver back to the sender.

Depending on the application, the URA-232-XT’s downstream RJ45 port can
connect to more receivers (URA-232-XT or URA-232). The constructed daisy chain
may have:

• Up to 3750 feet maximum cable from source to last URA-232

• A maximum of 5 URA-232-XT devices in any chain

• 750 feet maximum distance between units in a chain


2.8 Typical Block Diagram for UV232A-4S or UV232A-8S

Figure 2 – UV232A-4S & UV232A-8S Application Diagram