13.2 Resetting the control unit
This function allows you to reset the control unit (factory setting).
b
The resetting of factory settings is irreversible. Any
customised confi guration of the control unit will be
lost.
•
Simultaneously press the buttons
for 10
seconds.
•
Confi rm by pressing
.
14 Re-check and restart
•
Once the control unit is installed, check the operation.
•
Switch the control unit on to ensure that any adjustments
operate correctly and check that the appliance operates safely.
15 User information
At the end of the installation:
- explain the operation of the equipment and its safety devices
to the user, if necessary provide a demonstration and answer
any questions;
- give the user all the required documentation,
- fi ll in the documents where necessary;
- advise the user of the precautions necessary to prevent
damage to the system, appliance and the building;
- inform the user of the guarantee conditions,
- explain to the user the usage envelope of the appliance and
the limits of the manufacturer’s responsibility,
- remind the user to service the appliance annually.
MAINTENANCE
16 Trouble-shooting
16.1 Fault
diagnosis
The following checks should be performed before proceeding
onto specifi c diagnostics:
- Ensure that it has not been disconnected from the electricity
network and that the control unit is connected correctly.
- Ensure that all installation’s appliances are available.
- Check the functioning of external regulatory devices (room
thermostat, remote sensor,).
16.2 Maintenance
menu
16.2.1
Access to the maintenance menu
•
Press the “menu” button for 7 seconds.
•
Enter the installer maintenance access code 35.
•
Press the button
to confi rm.
The maintenance menu includes the installation menu function,
plus 2 additional functions:
- "System tests", within the maintenance menu,
- "After sales service Info", in the options.
16.2.2 System
tests
This menu allows you to test the operation of all the appliances
and the system (boiler, HP, valve,) present in the installation.
Each element can be controlled centrally by activating its normal
start-up function or by individual component.
i
By entering the test menu, the control unit display’s
the following message: “the system is currently
stopped" No further heating control operations are
aff ected. Control is resumed upon exiting the menus.
16.2.3
After sales service info
This menu provides access to After sales Service information:
- date of last access to installer menus
- the name of the company which provides the after sales
service, if entered during installation.
- the telephone number of the company which provides the after
sales service , if entered during installation.
16.3 System failure codes
i
Refer to the system manual. The breakdowns
described in the system manual must be handled by a
qualifi ed professional and, if necessary, by the after-
sales department.
The fault status may be “inactive” (disappeared) "active" (still
aff ects the installation).
The installation can operate partially with a fault “active”. It is not
necessarily “blocking”. An alarm (not supplied) can be added to
the installation to signal certain faults.