13 Replacement of Parts

13.10 Viewing Window

For access, refer to section 13.1.

Refer to diagram 13.4.

Remove circlip.

Remove steel washer.

Remove glass.

Remove fibre washer.

Replace in reverse order.

13.11 Heat Exchanger

Refer to Manual Handling section on page 5.

For access, refer to section 13.1.

Refer to section 11.3 for removal of the fan, gas valve and
burner assembly.

Drain the boiler.

Remove the clip securing the clear condense pipe to heat
exchanger.

Pull to remove the clear condense pipe out of the bottom of the
heat exchanger.

Undo the two nuts of the flow and return pipes from the heat
exchanger, see diagram 13.5.

Move the pipes away from the heat exchanger.

Loosen the three heat exchanger securing screws and clamps
(two at the top and one at the bottom) to remove the heat
exchanger, see diagram 13.5.

CAUTION: There will be water in the heat exchanger.

Remove clear condense pipe connector from bottom of heat
exchanger.

13.12 Flue Hood

For access, refer to section 13.1.

Remove heat exchanger as per section 13.11.

Remove the two securing screws and pull the flue hood down
and away from the flue hood bracket and flue elbow, see
diagram 13.6.

13.13 Heating Flow Thermistor

For access, refer to section 13.1.

Refer to diagram 13.7.

Remove the electrical connections from the thermistor.

Remove the retaining clip from the flow pipe.

Remove the thermistor from the retaining clip.

Note that the polarity of the wiring to thermistors is unimportant.

13.14 Heating Return Thermistor

For access, refer to section 13.1.

Refer to diagram 13.7.

Remove the electrical connections from the thermistor.

Remove the retaining clip from the flow pipe.

Remove the thermistor from the retaining clip.

Note that the polarity of the wiring to thermistor is unimportant.

Diagram 13.7

RETURN
PIPE

HEATING FLOW
THERMISTOR

HEATING RETURN
THERMISTOR

Diagram 13.5

FLOW AND
RETURN
PIPE NUTS

SECURING
SCREWS
AND
CLAMPS
(3 OFF)

OVERHEAT
THERMOSTAT

FLOW
PIPE

11411

FLUE HOOD

SECURING
SCREWS

Diagram 13.6

FLUE HOOD
BRACKET

11602

11404