1 technical information – Glow-worm hxi and Gas Valve User Manual

Page 10

background image

10

0020008153-05

48

66

53

113.5

133

375

54

30

13

CONDENSATE
DRAIN

600

48

73

334

176

33

600

MAX.

87

MIN.

GAS

TOTAL WEIGHT

GAS CONNECTION

Rc

1

/

2

(

1

/

2

in BSPT)

WATER CONNECTION 22mm. copper

ELECTRICITY SUPPLY 230V~50Hz fused 3A

ELECTRICAL RATING 60W

INTERNAL FUSE RATE Main PCB 630mAT

TABLE 1

12 hxi = 30kg
15 hxi = 30kg
18 hxi = 30kg
24 hxi = 33kg
30 hxi = 33kg
38 hxi = 33kg

1 Technical Information

Diagram 1.1

12856

CONDENSATE
DRAIN

INSIDE WALL
FIXING FACE

1.3 Gas Supply

The gas installation shall be in accordance with the relevant
standards.

In GB this is BS6891.

In IE this is the current edition of I.S.813 "Domestic Gas
Installations".

The supply from the governed meter must be of adequate size
to provide a steady inlet working pressure of 20mbar (8in wg)
(Propane G31, 37mbar) at the boiler.

On completion, test the gas installation for soundness using the
pressure drop method and suitable leak detection fluid, purge
in accordance with the above standard.