beautypg.com

9 installing the side cladding, 10 instructing the operator, 7 maintenance – Glow-worm Envirosorb3 User Manual

Page 24: 1 observing maintenance intervals, 2 preparing for maintenance, 1 procuring spare parts, 7maintenance

background image

7 Maintenance

24

Installation instructions Envirosorb₃ 0020154078_03

Envirosorb

3

8,

Envirosorb

3

11

Flow rate increase (l/h)

Temper-
ature
5 °C

Temper-
ature
15 °C

Temper-
ature
25 °C

Liquid
type

Water

0

0

0

60% alcohol

0

0

0

30% propylene
glycol

400

240

120

50% propylene
glycol

650

500

400

30% ethylene
glycol

120

0

0

50% ethylene
glycol

400

140

50

– Applies for: Envirosorb

3

15

Flow rate increase (l/h)

Temper-
ature
5 °C

Temper-
ature
15 °C

Temper-
ature
25 °C

Liquid
type

Water

0

0

0

60% alcohol

0

0

0

30% propylene
glycol

600

440

280

50% propylene
glycol

1050

740

580

30% ethylene
glycol

520

350

300

50% ethylene
glycol

880

680

540

Note
Insufficient purging may lead to deviations in the
flow rate.

If you cannot reach the minimum flow rate, install an ad-
ditional pump.

If you cannot reach the recommended flow rate, adjust
the heating circuit pressure on the controller and, if ne-
cessary, use a bypass valve (item 50).

6.9

Installing the side cladding

C

C

B

A

Install the side cladding.

6.10

Instructing the operator

1.

Explain the how the system operates to the operator.

2.

Draw particular attention to the safety information,
which the operator must follow.

3.

Make the operator aware of the need for regular main-
tenance (maintenance contract).

4.

Explain to the operator how to check the system's water
volume/filling pressure.

7

Maintenance

7.1

Observing maintenance intervals

1.

Only carry out maintenance work if you are a competent
person.

2.

Carry out annual maintenance.

7.2

Preparing for maintenance

7.2.1

Procuring spare parts

The original components of the product were also certified
as part of the CE declaration of conformity. Information about
available original spare parts is available by contacting the
contact address provided on the reverse of this document.

If you require spare parts for maintenance or repair work,
use only original spare parts.