8 mounting the boiler – Glow-worm Compact 80E User Manual
Page 18

18
221742D
7022
Diagram 8.9
UNION CONNECTION
DISCHARGE
PIPE
8 Mounting the boiler
SAFETY
VALVE
DISCHARGE
8080
Diagram 8.8
FITTED TO HYDRO BLOCK
SERVICE
COCKS (4)
GAS SUPPLY
SEAL
PRESSURE
GAUGE
CONNECTION
DISCHARGE
PIPE
7405
Diagram 8.7
8.5 Rear Outlet Flue Fixing
Make sure that the ductings do not slope down towards the
boiler.
Fit the air duct into the flue spigot by pulling the air duct into the
flue spigot, locating cutouts. Turn the air duct anti-clockwise to
lock into the cutouts, see diagram 8.10.
Note: It is important the correct restrictor plate is fitted or refitted,
see restrictor table.
Fit the flue connecting sleeve onto the fan, see diagram 8.11.
Fit the fan to the flue ducting, see diagram 8.11.
Fit the fan and flue collector the electrical connections and air
pressure tubes to the fan.
Refit the combustion chamber panel.
Make the outer wall weatherproof. A Flue Collar Kit Part No.
443286 is available.
8.6 Top Outlet Side or Rear Flue Fixing
Position the restrictor plate supplied in the loose items pack,
between the flue elbow and boiler , (gasket facing upwards). Fit
the flue elbow to the restrictor plate and top of the boiler using
the four screws supplied, see diagram 8.7.
Tighten the four screws of the flue elbow evenly to ensure a
good seal at the gasket.
Note: It is important the correct restrictor plate is fitted or omitted
where instructed.
For top flue outlet be sure to use the correct restrictor plate, all
restrictors are supplied with the appliance, see restrictor table.
RESTRICTOR/
GASKET
FLUE ELBOW
(REAR FLUE
SHOWN)
SECURING
SCREW (4)
PRODUCTS
PROBE
FLUE OUTLET
MAX.
USE RESTRICTOR
FLUE
PLATE MARKED
LENGTH
1. REAR
0M to 0.5M
COMP 75E/80E
0.5M-MAX
or
'F'
2. REAR
0.5M to 2.5M
COMP 75E/80E
0.5m-3.5M
or
'G'
3. TOP
0M to 2.5M
COMP 75E/80E
2.5M-MAX
or
'E'
RESTRICTOR TABLE
SEALING
WASHER (4)
(INSERT INTO
TUBING NUT)