7 flue preparation – Glow-worm Compact 80E User Manual
Page 14

14
221742D
7 Flue Preparation
Diagram 7.1
7510
7639
TOP OUTLET/
REAR FLUE
TOP OUTLET/
SIDE FLUE
15mm
VIEW ’B’
VIEW ’B’
15mm
STD./EXTD. TOP OUTLET FLUE PACK & 1 METRE EXTENSION KIT
SCREW
& TAPE
SCREW
& TAPE
SCREW
& TAPE
SCREW
& TAPE
2 x 1 metre extension kits may be joined together.
FLUE LENGTH
MAX 840mm (extd.)
MAX 570mm (std)
FLUE LENGTH
MAX 840mm (extd.)
MAX 570mm (std)
15mm
SCREW
& TAPE
239mm
54mm
TOP OUTLET FLUE PACK
’X’
RHD SIDE FLUE ’X’ plus 254mm = FLUE LENGTH
LHD SIDE FLUE ’X’ plus 10mm = FLUE LENGTH
RHD SIDE FLUE ’X’ plus 254mm = FLUE LENGTH
LHD SIDE FLUE ’X’ plus 10mm = FLUE LENGTH
REAR FLUE ’Y’ plus 69mm = FLUE LENGTH
’Y’
’X’
15mm
SCREW
& TAPE
’Y’
’Y’ plus 69mm = FLUE LENGTH
’Y’
FLUE LENGTH
510mm MAX.
15mm
80mm
REAR OUTLET FLUE PACK
SCREW
& TAPE
SCREW
& TAPE
FOAM
SEAL
5mm
’Y’ plus 95mm = FLUE LENGTH
’Y’
80mm
REAR OUTLET FLUE PACK & 1 METRE EXTENSION KIT
FOAM
SEAL
’Y’ plus 95mm = FLUE LENGTH
2 x 1 metre extension kits may be joined together.
TOP STD.
REAR
SIDE R.H.
SIDE L.H.
TOP EXTD.
REAR
SIDE R.H.
SIDE L.H.
REAR STD.
REAR
75
170
510
415
-
MINIMUM
WALL
THICKNESS
MINIMUM
FLUE
LENGTH
MAXIMUM
FLUE
LENGTH
"Y"
BOILER MOUNTING FACE
TO EXTERNAL WALL FACE
"X"
BOILER CASING TO
EXTERNAL WALL FACE
MAXIMUM DISTANCE FROM
144
334
90
500
-
-
-
316
560
75
75
75
75
75
75
144
334
90
840
840
840
770
-
-
-
586
830
570
570
570
FLUE
PACKS
NOTE :
IF IT IS NECESSARY TO CUT THE DUCTS
TO ACHIEVE THE "FLUE LENGTH" MAKE SURE
THAT THE OVERLAPS ARE AS FOLLOWS :-
THE OVERLAP FOR AIR DUCT = 25mm
THE OVERLAP FOR FLUE DUCT = 50mm
THE MAXIMUM LENGTHS CAN BE INCREASED
BY AN ADDITIONAL 2 METRES WITH THE USE
OF THE 1 METRE EXTENSION KITS.
NOTE :
THIS APPLIES TO STANDARD KITS ONLY.