A technical specifications, Mportant, Maxtester copper test – EXFO MaxTester MAX-610 User Manual
Page 273: Copper specifications

MaxTester Copper Test
265
A Technical Specifications
I
MPORTANT
The following technical specifications can change without notice.
The information presented in this section is provided as a reference
only. To obtain this product’s most recent technical specifications,
visit the EXFO Web site at www.exfo.com
COPPER SPECIFICATIONS
a, b, c
Transmitter characteristics
Frequency range (200 Hz to 20 kHz)
Frequency resolution
1-Hz steps
Frequency uncertainty (accuracy)
±(50 ppm + 1 Hz)
Level range (dBm)
–20 to 10 at 600
1
Level resolution
0.1 dB
Level uncertainty (accuracy)
±1 dB
Impedance (
1)
600
Frequency range (20 kHz to 2.2 MHz)
Frequency resolution
1-kHz steps
Frequency uncertainty (accuracy)
±(50 ppm + 100 Hz)
Level range (dBm)
–20 to 10 at 100
1
Level resolution
0.1 dB
Level uncertainty (accuracy)
±1 dB
Impedance (
1)
100, 120, 135, 150
Frequency range (2.2 MHz to 30 MHz)
Frequency resolution
1-kHz steps
Frequency uncertainty (accuracy)
±(50 ppm + 100 Hz)
Level range (dBm)
–20 to 0 at 100
1
Level resolution
0.1 dB
Level uncertainty (accuracy)
±1 dB
Impedance (
1)
100, 120, 135, 150
Receiver characteristics
Reception frequency range
200 Hz to 20 kHz
20 kHz to 30 MHz
Frequency uncertainty range (accuracy)
±(50 ppm + 1 digit)
VF reception level range (dBm)
–90 to 15 at 600
1
VF level uncertainty (accuracy)
200 Hz to 20 kHz
–90 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB
WB reception level range (dBm)
–90 to 15 at 100
1 and 135 1
WB level uncertainty (accuracy)
20 kHz to 2.2 MHz
–90 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB
2.2 MHz to 30 MHz
–90 dBm to –50 dBm, uncertainty (accuracy) ±2 dB
–50 dBm to 15 dBm, uncertainty (accuracy) ±1 dB
Impedance (
1)
100, 120, 135, 150, 600
POTS dialer
DTMF
0 – 9, #, *
Phonebook
25 entries
Digital multimeter (DMM)
Test type
Snapshot and continuous
Impedance selection (for voltage measurement)
100 k
1, 1 M1
Measurement
Range
Resolution
Uncertainty (accuracy)
DC voltage
0 to 400 V
0.1 V for 0 to 99.9 V
1 V for 100 V to 400 V
±(|1 %| + 0.5 VDC)
AC voltage
0 to 280 Vrms
0.1 V for 0 to 99.9 V
1 V for 100 V to 280 V
±(1 % + 0.5 VAC)
Isolation resistance
(stress/leakage)
0 to 1 G
1, auto-ranging
1 k
1 to 99 M1
100 M
1 to 999 M1
Three digits
±(2 % + 1 digit)
±(5 % + 1 digit)
Resistance
0 to 100 M
1
0 to 999
1
1 k
1 to 100 M1
Three digits
±(1 % + 5
1)
±(2 % + 1 digit)
Capacitance
0.1 nF to 2 μF
Four digits
±(2 % + 50 pF)
DC current
0 to 110 mA
0.1 mA
±(|2 %| + 1 mA)
AC current
0 to 110 mA
0.1 mA
±(|2 %|+ 1 mA)
d
Station Ground
0 to 1 M
1
0 to 999
1
1 k
1 to 1 M1
Up to three digits
±(1 % + 3
1)
±(2 % + 1 digit)
NOTES
a. Subject to change without notice.
b. Typical, at 23 °C ± 3 °C, on batteries, with no type B USB connection.
c. Specifications based on 24 AWG (PE 0.5 mm) cabling.
d. From 10 mA to 110 mA.