beautypg.com

ENMET EX-2000 User Manual

Page 7

background image

EX2000

ENMET Corporation

3

2.0

2.0

2.0

2.0 EX-2000

EX-2000

EX-2000

EX-2000 Features

Features

Features

Features

See figure 1 for location of features listed below.

Feature

Description

Display

The Liquid Crystal Display(LCD) allows messages to be read clearly:

4 digits (7 segments), for displaying the measurement

3 digits (14 segments), for displaying symbols such as: LEL, MIN, MAX, TST,

OFF, CH4 etc …

3 arrowhead symbols to indicate the parameter scrolling menu is used to

indicate: Up, Down and Negative indicators

4 pictograms supplementing the audio and visual alarms relating to the

exceeding of thresholds, battery faults, maintenance mode etc…

Equipped with backlight by Light-Emitting Diodes (LED)

ENTER Switch

Red oval pushbutton switch on the front of the

EX-2000

, below the display.

Switching the instrument on or off

Enter, confirmation

BACKLIGHT / MINUS
Switch

Round w/down pointing triangle pushbutton switch on the front of the

EX-2000.

Backlighting the display

Scrolling the parameters and menus

“Minus ” switch, during programming or calibration

confirmation of "yes" or "no", during programming or calibration

ALARM / PLUS

Switch

Round w/up pointing triangle pushbutton switch on the front of the

EX-2000.

Clears the gas alarms

“Plus” switch, during programming or calibration

Visual Alarm

Red indicator clearly visible on 3 sides and located at the top of the instrument

Audio Alarm

Loud buzzer located on the front panel of the instrument

Sensor

Located under the sensor cover on the top of the

EX-2000

The target gas will be labeled on the left side of the

EX-2000

Belt Clip

Clip to outside of clothing for hands-free operation

Programming / Charge
Port

Located at the left side of the

EX-2000

under an attached cover.

To plug-in battery charger

To plug-in programming plug

Programming Plug

Used to access the Programming and Calibration Menus for Maintenance

2.1 Power supply

The

EX-2000

is powered by 3 batteries either alkaline or optional rechargeable.

• The 3 AA alkaline will last 12 hours when used under normal conditions. When replaced they must be replaced with

Duracell MN 1500

• The 3 optional cadmium-nickel rechargeable will last 30 hours when used under normal conditions. When replaced they must

be replaced with

Panasonic P80 AA, 1V2/800 mAH

W

ARNING

:

Substitution of batteries or other components may compromise the intrinsic safety of the

instrument.