To calibrate an
EX-2000
with a gas other than the programmed/labeled gas refer to the coefficient table below.
We recommend using 50% LEL levels of gases. Other levels are acceptable.
Example: Ethyl Acetate recommended calibration gas is Butane and its coefficient factor is 0.9
50%LEL multiplied by the coefficient of the programmed gas 0.9 equals 45.
Apply the 50%LEL Butane to the instrument and adjust the reading on the display to read 45. Calibration is complete.
Table 1: Coefficients of Gases Detected
Gas
Empirical
Formula
%LEL
Recommended
Cal. gas / Coefficient
Ethyte acetate
C4H8O2
2.1 %
Butane
0.9
Acetone
C3H6O
2.15 %
H2
2.6
Acetylene
C2H2
1.5 %
H2
1.8
Ammonia
NH3
15.0 %
H2
0.85
Benzene
C6H6
1,2 %
Butane
1.5
1, 3-Butadiene
C4H6
1.4 %
H2
2.1
Butane
C4H10
1.5 %
Butane
1.0
2–Butanone (MEK)
C4H8O
1.8 %
Butane
1.2
Dimethylether
C2H6O
3.0 %
Butane
1.0
Unleaded gasoline
Mixture
1.1 %
Butane
1.6
Gasoline
Mixture
1.3 %
Butane
1.4
Ethane
C2H6
3.0 %
CH4
1.1
Ethanol
C2H6O
3.3 %
H2
1.95
Ethylene
C2H4
2.7 %
H2
1.7
Diesel oil
Mixture
0.6 %
Butane
3.25
Natural gas
CH4
5.0 %
CH4
1.05
L.P.G.
Prop+But
1.65 %
Butane
1.35
Heptane
C7H16
1.1 %
Butane
1.95
Hexane
C6H14
1.2 %
Butane
1.15
Hydrogen
H2
4.0 %
H2
1.0
Isobutane
C4H10
1.5 %
Butane
1.05
Isopropanol
C3H8O
2.15 %
Butane
1.05
Kerosene (JP4)
C10 - C16
0.7 %
Butane
4.85
Methane
CH4
5.0 %
CH4
1.0
Octane
C8H18
1.0 %
Butane
2.25
Ethylene oxide
C2H4O
2.6 %
Butane
1.35
Propylene oxide
C3H6O
2.3 %
Butane
1.3
Pentane
C5H12
1.4 %
Butane
1.05
Propane
C3H8
2.0 %
Propane
1.3
Propylene
C3H6
2.0 %
Butane
0.8
Styrene
C8H12
1.1 %
Butane
1.6
Toluene
C7H8
1.2 %
Butane
1.35
White Spirit
Mixture
1.1 %
Butane
3.25
Xylene
C8H10
1.0 %
Butane
1.6