EX-6100
ENMET Corporation
2
2.0 Features of the EX-6100
The
EX-6100
is an ATEX and IECEx certified fixed gas detector for use in potentially explosive atmospheres. The unit may be
optionally fitted with a protective weather guard as shown in the photograph.
The unit comprises an instrument housing having two cable gland entries and containing the connection terminals, electronics and display
window.
The housing containing the gas sensor has an M27 thread and is screwed into the bottom of the unit. The sensor housing itself is a certified
component and must not be removed in service.
Behind the display window are-
See Figure 1 for location of features:
Feature
Description
Display
A 4-digit LCD display
Magnetic Switches
Four magnetically operated switches that are activated through the display window using a magnetic
pen that is supplied with the unit.
Visual Indicators
LED indicators for POWER, ALARM & KEY PRESS
Power supply
8 to 24 volts dc (non-intrinsically safe)
Analogue output
4 to 20mA dc
Communications Output
RS232
Relay
Relay version has 3 factory-fitted relays. Each provides a set of voltage free changeover contacts to
perform the following control functions contact outputs for Alarm Level 1, Alarm Level 2 and Fault
Gland (Strain Relief)
entry threads available – 20mm, ½” or ¾” NPT
Magnetic switches control the instrument maintenance functions. The magnetically operated switches allow the unit to be
calibrated while power is still applied without the need to remove the cover from the unit.
Versions without relays fitted are also available.
The self-adhesive label on the outer surface of the enclosure indicates whether or not the relays are fitted as shown below:
IMPORTANT
– When used in environments where the instrument is exposed to salt spray or diesel it is recommended that the
EX-6100
is always fitted with its protective weather guard. The weather guard is attached with tamperproof screws to
ensure that it is not inadvertently removed.
Figure 1: EX-6100 Features
GAS DETECTOR TYPE
CONTROL RELAYS FITTED
GAS DETECTOR TYPE
NO CONTROL RELAYS FITTED
2 x 0.27 (2 x 7) dia.
Mounting Holes
Optional
Weatherguard
Inlet/Outlet
Port 1 of 2
Display
Menu Switches
Power & Alarm LEDs
Inlet/Outlet
Port 1 of 2
MENU UP DOWN ENTER