beautypg.com

ENMET EX-6100 Series User Manual

Page 5

background image

EX-6100

ENMET Corporation

2

2.0 Features of the EX-6100

The

EX-6100

is an ATEX and IECEx certified fixed gas detector for use in potentially explosive atmospheres. The unit may be

optionally fitted with a protective weather guard as shown in the photograph.

The unit comprises an instrument housing having two cable gland entries and containing the connection terminals, electronics and display
window.

The housing containing the gas sensor has an M27 thread and is screwed into the bottom of the unit. The sensor housing itself is a certified
component and must not be removed in service.

Behind the display window are-

See Figure 1 for location of features:

Feature

Description

Display

A 4-digit LCD display

Magnetic Switches

Four magnetically operated switches that are activated through the display window using a magnetic
pen that is supplied with the unit.

Visual Indicators

LED indicators for POWER, ALARM & KEY PRESS

Power supply

8 to 24 volts dc (non-intrinsically safe)

Analogue output

4 to 20mA dc

Communications Output

RS232

Relay

Relay version has 3 factory-fitted relays. Each provides a set of voltage free changeover contacts to
perform the following control functions contact outputs for Alarm Level 1, Alarm Level 2 and Fault

Gland (Strain Relief)

entry threads available – 20mm, ½” or ¾” NPT

Magnetic switches control the instrument maintenance functions. The magnetically operated switches allow the unit to be
calibrated while power is still applied without the need to remove the cover from the unit.

Versions without relays fitted are also available.

The self-adhesive label on the outer surface of the enclosure indicates whether or not the relays are fitted as shown below:

IMPORTANT

– When used in environments where the instrument is exposed to salt spray or diesel it is recommended that the

EX-6100

is always fitted with its protective weather guard. The weather guard is attached with tamperproof screws to

ensure that it is not inadvertently removed.

Figure 1: EX-6100 Features

GAS DETECTOR TYPE

CONTROL RELAYS FITTED

GAS DETECTOR TYPE

NO CONTROL RELAYS FITTED

2 x 0.27 (2 x 7) dia.

Mounting Holes

Optional
Weatherguard

Inlet/Outlet

Port 1 of 2

Display

Menu Switches

Power & Alarm LEDs

Inlet/Outlet
Port 1 of 2

MENU UP DOWN ENTER