9 Certification

The

EX-6100

/FGD10 Series of Gas Detectors are ATEX and IECEx certified for use in potentially explosive atmospheres and

is marked as follows:-

** Denotes additional characters that define the gas detector configuration e.g. Enclosure type and sensor arrangement.

YYYY – Denotes year of manufacture.

Special Conditions of Safe Use

Only Loctite 243 or a compound of equal strength shall be reapplied to the threads of the sensor after replacing the sensing
element

Electrical data

Power supply - 8Vdc to 24Vdc, 5W

Relay contact rating – 300Vac, 3 Amps

Installation instructions

The cable entry devices and blanking elements of unused apertures shall be of a certified flameproof type, suitable for the
conditions of use and correctly installed.

With the use of conduit, a suitable certified sealing device such as a sealing fitting with compound shall be provided
immediately at the entrance to the flameproof enclosure.

10 EX-6100 Accessories and Calibration Gas

EX-6100

accessories and calibration gas

ENMET

part number

Description of Accessory

Part Number

Sensor

03070-007

Calibration Adaptor

03700-057

Regulator Assembly

02506-004

Calibration Gas, 50%LEL Methane

03220-050

Calibration Gas, 50%LEL Propane

03221-050

Calibration Gas, 50%LEL Hydrogen

03227-050

Calibration Gas, 50%LEL Butane

03282-050

Weather Guard

04546-012

Maintenance Tool, Sensor

73413-210

WARNING – DO NOT OPEN WHEN AN EXPLOSIVE GAS

ATMOSPHERE IS PRESENT

GAS DETECTOR TYPE FGD10 **

STATUS SCIENTIFIC

IECEx SIR 08.0009X

CONTROLS LTD.

T4 (Ta -20

O

C to +60

O

C)

MANSFIELD

T5 (Ta -20

O

C to +50

O

C)

NG18 5ER.UK.

T6 (Ta -20

O

C to +35

O

C)

II 2 G Ex d IIC 1180

SIRA 08ATEX1031X

SERIAL No. XXXXXX

CIRCUIT RATING: 24VDC, 5W

YYYY

RELAY CONTACT RATING:

300VAC. 3A MAX.