4.0 Troubleshooting RECON-IS

Problem Possible

reason

Solution

The detector cannot be

turned on

Battery used up

Please contact ENMET.

Circuit fault

Contact the distributor or ENMET.

No response to the gas

Warm-up not finished

Wait till warm-up is finished

Circuit fault

Contact the distributor or ENMET.

Testing not accurate

Sensor is end-of-life

Contact the distributor or ENMET.

Not calibrated for long time

Calibrate it in time.

Gas level is negative

Sensor drift

Calibrate zero point

Zero calibration
unavailable

Too much sensor drift

Calibrate or replace the sensor

5.0 Sensor Replacement

Warning

: the replacement sensor must be the same type as the sensor to be replaced.

Remove retaining screw, open the RECON-IS, pull out the present gas sensor (If the sensor is too tight, please shake it slightly
and then pull out it). And then put new gas sensor into the sensor socket. Make sure the sensor plug and socket is
corresponding. After replacement, screw on the retaining screw.

Caution: When plugging in the gas sensor, please don’t use too much pressure. Otherwise, the sensor may be damaged.

After replacement, please calibrate the sensor after the detector works for 30 minutes.

Figure 4: Replacing RECON-IS Sensor

5.1 Replacement Sensors

ENMET replacement sensor part numbers:

Table 2: Sensor Part Numbers

Description of Part

Part Number

Sensor H2S

02542-0200

Sensor O2

02542-1100

Sensor CO

02542-1200

N

OTE

: Contact

ENMET or local distributor for additional sensor information.

Sensor

Sensor Socket

Screw