Appendix A: Serial Remote Control (RS-232)
The DCC2 is equipped with a 9-pin RS-232 connector for system remote control via a
serial cable (not provided by EMM Labs). The cable should be non-crossed for
connections between a PC and the DCC2. The parameters and settings for this link are:
• 19,200
baud
• 8
bits
• 1 stop bit
• no flow control
• no parity bit
Commands to DCC2
All commands sent to the DCC2 consist of 3 ASCII characters followed by a
Repeating a
the volume of the DCC2 over a wide range. Received commands are not stored in a
stack and, therefore, need to be sent in intervals of at least 30ms to allow enough time for
the DCC2 to execute a command before receiving the next one.
Char 0
Char 1
Char 2
Char 0
>30ms
mut
Toggles mute on / off
wbw
Select wide bandwidth for digital audio playback
nbw
Select narrow bandwidth for digital audio playback
pol
Toggles polarity of all analog outputs inversed / normal
48k
Selects 48kHz base sample frequency
44k
Selects 44.1kHz base sample frequency
clk
Toggles external clock selection on / off
pst
Selects PCM input on ST glass connectors
tos
Selects PCM input on TOSLink connector
cox
Selects PCM input on coax connector
aes
Selects PCM input on AES/EBU connectors
dst
Selects DSD input on ST glass connectors
bnc
Selects DSD input on BNC connectors
rca
Selects analog input on RCA connectors
xlr
Selects analog input in XLR connectors
don
Turns front panel display on
dof
Turns front panel display off (unit keeps operating)
pon
Turns power on from standby
pof
Turns DCC2 into standby operation
vup
Moves volume up by 1 step (repeat only
vdn
Moves volume down by 1 step (repeat only