beautypg.com

Warning, Caution, Before starting – EarthQuake 60005072 User Manual

Page 11

background image

Operator's Manual

Viper Engine, 159cc

Check for parts online at

www.ardisam.com or call 800-345-6007 M-F 8-5

11

WARNING

cARbon MonoxIde GAs Is ToxIc. InHAlA-

TIon cAn cAuse unconscIousness And

deATH.
neVeR leAVe enGIne RunnInG WHIle un-

ATTended.
do noT ATTeMPT To sTART enGIne In THe

folloWInG WAYs:
• dO nOT use sTarTing Fluid.
• dO nOT spray Flammable liquids Or

VAPoRs InTo AIR fIlTeR, cARbuReToR oR

sPARk PluG cHAMbeR.

• dO nOT remOve spark plug and pull

on sTARTeR RoPe. flAMMAble fuel cAn

sPRAY ouT And IGnITe fRoM A sPARk

fRoM sPARk PluG.

befoRe sTARTInG

enGIne oIl

enGIne oIl RecoMMendATIons
Oil is a major factor affecting performance and service
life. Use 4-stroke automotive detergent oil.
SAE 10W-30 is recommended for general use. Other
viscosities shown in the chart may be used when the
average temperature in your area is within the recom-
mended range.

The SAE oil viscosity and service classification are in the
API label on the oil container. We recommend that you
use API SERVICE Category SE or SF oil.

To check the oil
• Check the engine oil level with the engine stopped

and in a level position.

• Remove the oil filler cap/dipstick and wipe it clean.
• Insert the oil filler cap/dipstick into the oil filler neck as

shown, but do not screw it in; then remove it to check
the oil level.

• If the oil level is near or below the lower limit mark

on the dipstick, fill with the recommended oil to the
upper limit mark. Do not overfill.

• Reinstall the oil filler cap/dipstick.
NOTE:

engine oil capacities
0.55L (0.146 US Gal, 0.119 Imp Gal)

CAUTION

THIs enGIne Is sHIPPed fRoM fAcToRY

WITHouT oIl. cHeck oIl leVel befoRe

sTARTInG enGIne. If You sTART THe en-

GIne WITHouT oIl, THe enGIne WIll be

dAMAGed beYond RePAIR And WIll noT

be coVeRed undeR WARRAnTY.

OIL FILLER CAp/DIpSTICk

UppER

LOWER

Figure 2: Checking the oil level

CAUTION

do noT oVeRfIll. oVeRfIllInG WITH oIl

MAY cAuse sMokInG, HARd sTARTInG,

sPARk PluG foulInG, oR oIl sATuRATIon

of AIR fIlTeR. used oIl sHould be senT To

sPecIAl RecYcle bIn foR dIsPosInG.

-20 0 20 40 60 80 100

o

f

-30 -20 -10 0 10 20 30 40

o

c

10W-30

30

5W-30

AMbIenT TeMPeRATuRes

sAe VIscosITY GRAdes