Beckett NX: System and General Troubleshooting

Problem

Possible Cause

Remedy

Boiler will not start.

Thermostat not calling for heat.

No power to Boiler.

Thermostat faulty.

Oil primary control faulty.
Photo Cell wiring shorted or

room light leaking into photo cell

compartment

Open safety switch.

Boiler will not start without

fi rst pushing oil primary

control reset button.
(Happens on frequent basis)

Photo Cell (Cad Cell) defective.

No fuel oil.

Clogged nozzle.

Clogged oil fi lter.

Blocked Vent Safety Circuit opening.

Low oil pump pressure.

Air getting into fuel oil lines, or fuel

oil line dirty, clogged, or in some

manner defective.

Defective burner motor.

Boiler starts, but cuts out

requiring manually resetting

the oil protector reset button

No fuel oil.

Clogged nozzle.

Clogged oil fi lter.

Blocked Vent Safety Circuit opening.

Low oil pump pressure.

Air getting into fuel oil lines, or fuel

oil line dirty, clogged, or in some

manner defective.

Defective burner motor.

Water or contaminants in oil.

OPERATION AND TROUBLESHOOTING