Push “SELECT” switch to increment the menu to the next alarm function.
A
L
L
A
L
A
R
M
S
O N O F F > S E T U P <
Alarm Output 1 – RF Carrier Loss (alarm based on analog RF signal strength)
• Highlight desired “SET” or “OFF” option using UP and DN switches to toggle the
setting. Select “SET” to set this monitor alarm and continue with alarm configuration
menu; select “OFF” to set this monitor alarm function to off. Push “SELECT” to
continue.
R F C A R R I E R L O S S
>
S
E
T
<
O
F
F
• If “SET” is selected, submenu for “Level” threshold with “LOW”, “MED” and “HIGH”
options is displayed next. “LOW” option sets RF carrier loss threshold for
approximately 10µV (25dBf); “MED” option sets RF carrier loss threshold for
approximately 100µV (45dBf); and “HIGH” option sets RF carrier loss threshold for
approximately 3KµV (75dBf). Use UP and DN switches to toggle the setting and
highlight the desired option.
R F C A R R I E R L E V E L
L O W > M E D < H I G H
Push “SELECT” switch to increment the menu to the next alarm function.
• Submenu for “Alarm Delay” with “30”, “60”, “120” and “240” second options is
displayed next. Use UP and DN switches to toggle the setting and highlight the
desired option.
A L A R M D E L A Y
3 0 > 6 0 < 1 2 0 2 4 0 S
Push “SELECT” switch to increment the menu to the next alarm function.
Alarm Output 2 – Audio Loss (Silence Detect)
• Highlight desired “SET” or “OFF” option using UP and DN switches to toggle the
setting. Select “SET” to set this monitor alarm and continue with alarm configuration
menu; select “OFF” to set this monitor alarm function to off.