Configure Your FuzzyScan

66

PROGRAM

Operation Control

(All Series)

Reread Delay & Good Read Delay Control

F_DEFAULT

Family Code Selection

P.C

Parameter Selection

Option Code

Reread Delay

(Double Scan Verification)

SS
SS
SS
SS
SS
SS

Disable
Immediate time out
Short time out
Medium time out
Long time out
Force verification

0
1
2
3
4
5

Good Read Delay

SS
SS
SS
SS
SS
SS
SS

None
200 msec.
500 msec.
1 sec.
1.5 sec.
2 sec.
3 sec.

0
1
2
3
4
5
6

The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification

will not allow reading of the same bar code twice.

This Good Read Delay is the minimum amount of time before the imager can read another bar code.