Empty the drain tank, Operation (cont.) – DENSO CORPORATION MOVINCOOL OFFICE PRO 24 User Manual
Page 20

*
OPERATION (cont.)
Empty the Drain Tank
During COOL mode, condensate will accumulate in the drain tank.
When the drain tank becomes full, the FULL TANK LED will flash
and the LCD displays “Tank FL” and the ALARM signal output
is turned ON and the unit will shut off automatically.
*
Not available for OP 12 model
1) Open the drain tank door.
2) Pull the drain tank from the unit
(display will show “TANK” and
ALARM signal output stays ON).
3) Remove the cap and empty the
drain tank.
4) Replace the cap and return the drain tank to the unit.
5) Close the drain tank door.
6) Press the COOL ON/OFF button to continue running the unit,
display and ALARM signal will return to normal operation.
20
NOTE : If you want to empty the drain tank, while the unit is in
operation, press the COOL ON/OFF button to turn the unit off.
CAP