Operating Modes
1) COOL Mode
2) Temperature Control
3) Fan Mode Control DIP Switch
4) Temperature Scale Display DIP Switch
OPERATION (cont.)
The Office Pro 12, Office Pro 18, and Office Pro 24 can be
operated in two modes, Fan Only and COOL. When in Fan Only
mode, the unit circulates the surrounding air. When in COOL
mode, the compressor is operational and cool air is circulated.
Once the compressor has been disengaged for more than 120
seconds, the unit will operate in Fan Only mode for
approximately 5 seconds before the compressor re-engages.
(Time delay setting is around 120 seconds)
The room temperature thermistor monitors the inlet
temperature versus SET POINT temperature and switches
the unit automatically between COOL and Fan Only modes.
The Fan Mode Control DIP Switch determines whether the
FAN will continue to operate or stop when the compressor
cycles off. (SET POINT temperature equals inlet air or room
temperature.) The unit has been preset at the factor for
continuous fan operation.
The Temperature Scale Display DIP Switch changes the
temperature(s) that are displayed to either
°C
or °F .
The unit has been preset from the factory to display the
temperature(s) in °F.
NOTE : If you wish to change the fan mode operation
(COOL_OPERATE to COOL_STOP),
and/or the Temperature Scale
Display (°F to °C), contact your MovinCool reseller.