PRELIMINARY
4
Introduction
eSATA
1 eSATA interface connectors on rear panel for
storage expansion
Mechanical
Dimensions
230 mm (W) x 205 mm (D) x 75 mm (H) (9” x 8” x
2.5”)
Weight
3.8 kg (8.39 lb)
Mounting
Wall-mount kit
Environmental
Operating Temperature
Standard: 0°C to 50°C
Extended temperature: -20°C to 60°C (w/
industrial SSD or CFAST)
Storage Temperature
-40°C to 85°C (excl. HDD/SDD/CFAST)
Humidity
Approx. 95% @ 40°C (non-condensing)
Vibration
Operating, 0.5 Grms, 5-500 Hz, 3 axes (w/ HDD)
Operating, 5 Grms, 5-500 Hz, 3 axes (w/ SSD,
CFast)
ESD
Contact +/-4 KV and Air +/-8 KV
Shock
Operating, 50 G, half sine 11 ms duration (w/
CFAST or SSD)
Power Consumption
Power off
2.16 W
In shutdown mode with DC input and
only USB keyboard/mouse
System Idle
13.44 W
Under Windows Desktop with no
application programs executed
Processor full
load
47.04 W
Under Windows with 100% CPU
utilization and 2D/3D graphics load
System full load 92.4 W
Under Windows with 100% CPU
utilization and simultaneous access to all
I/O devices.
Recommended
power supply
160W
With consideration of voltage de-rating
under high environmental temperature.