4.28 Set Backlight PWM
This command sets the duty of Backlight control output. The value of the PWM also controls the
Backlight enable output. In case of PWM=0, the Backlight enable output will go inactive.
START SMC_addr ACK command ACK length ACK PWM_value ACK STOP
Table 4.28.1 SMC receiver format of the Set Backlight PWM Command Code
ITEM
DESCRIPTION
START
SM-bus start condition
SMC_addr
01010000b = 0x50 (8-bit, write access to SMC)
ACK
SM-bus acknowledge condition generated by receiver
command
0x80 = “Set Backlight PWM” Command code
length
0x01 = Length of this Command
PWM_value
Duty setting (0-255)
STOP
SM-bus stop condition
Table 4.28.2 Explanation of Table 4.28.1
4.29 Get Backlight PWM
This command reads the current duty of the Backlight control output.
START SMC_addr ACK command ACK length ACK PWM_value ACK STOP
Table 4.29.1 SMC receiver format of the Set Backlight PWM Command Code
ITEM
DESCRIPTION
START
SM-bus start condition
SMC_addr
01010000b = 0x50 (8-bit, write access to SMC)
ACK
SM-bus acknowledge condition generated by receiver
command
0x80 = “Set Backlight PWM” Command code
length
0x01 = Length of this Command
PWM_value
Duty setting (0-255)
STOP
SM-bus stop condition