14 get startup-temperatures of cpu and board – ADLINK CoreExpress-ECO2 User Manual
Page 22
4.14 Get Startup-Temperatures of CPU and Board
This command reads the CPU and Board Temperatures at power-on time. The temperatures are
transmitted in a signed char Bytes.
START
SMC_addr
ACK command
ACK START (Repeat)
SMC_addr+1
ACK
length
ACK(C) CPU_temp
ACK(C)
Board_temp ACK(C) STOP
Table 4.14.1 SMC transmitter format of the Get Startup-Temperatures of CPU and Board Command
ITEM
DESCRIPTION
START
SM-bus start condition
SMC_addr
0x50 (8-bit)
ACK
SM-bus acknowledge condition generated by receiver
command
0x3A = “Get Startup-Temperatures of CPU and Board” Command code
Length
0x02 = 2 Bytes data length
CPU_temp
CPU temperature at Startup. The format of this byte is signed char.
Board_temp
Board temperature at Startup. The format of this byte is signed char.
STOP
SM-bus stop condition
- USB-1901 (84 pages)
- USB-1210 (54 pages)
- USB-2401 (60 pages)
- USB-7230 (50 pages)
- USB-2405 (56 pages)
- DAQe-2010 (92 pages)
- DAQe-2204 (100 pages)
- DAQe-2213 (94 pages)
- DAQe-2501 (74 pages)
- PXI-2010 (84 pages)
- PXI-2020 (60 pages)
- PXI-2501 (62 pages)
- cPCI-9116 (98 pages)
- ACL-8112 Series (93 pages)
- ACL-8112 Series (94 pages)
- ACL-8112 Series (92 pages)
- ACL-8216 (75 pages)
- ACL-8111 (61 pages)
- PCM-9112+ (10 pages)
- PCM-9112+ (94 pages)
- cPCI-6216V (47 pages)
- ACL-6126 (28 pages)
- ACL-6128A (40 pages)
- PCM-6308V+ (52 pages)
- PCM-6308V+ (4 pages)
- PCI-7444 (82 pages)
- PCI-7434 (48 pages)
- PCI-7234 (56 pages)
- PCI-7260 (66 pages)
- PCI-7258 (38 pages)
- PCI-7256 (48 pages)
- PCI-7250 (48 pages)
- LPCI-7250 (48 pages)
- PCI-7396 (65 pages)
- PCI-7296 (59 pages)
- PCI-8554 (67 pages)
- PCIe-7360 (94 pages)
- PCIe-7350 (86 pages)
- PCIe-7300A (114 pages)
- PCIe-7200 (51 pages)
- PCI-7300A (83 pages)
- PCI-7300A (112 pages)
- PCI-7200 (96 pages)
- cPCI-7300 (82 pages)
- cPCI-7300 (83 pages)