9 read smc flags – ADLINK CoreExpress-ECO2 User Manual

Page 18

background image

4.9 Read SMC Flags

This command reads the SMC Flags and gives an information of the internal status of the SMC.

START

SMC_addr

ACK command

ACK START (Repeat)

SMC_addr+1

ACK

length

ACK(C) data

ACK(C) STOP

Table 4.9.1 SMC transmitter format of the Read BIOS Flags Command Code

ITEM

DESCRIPTION

START

SM-bus start condition

SMC_addr

0x50 (8-bit)

ACK

SM-bus acknowledge condition generated by receiver

command

0x35 = “Read SMC Flags” Command code

length

0x01 = 1 Bytes data length

data

Reflects the SMC status

Bit 5-7: System State

0 = S0-State
3 = S3-State

5 = S5-State
other values are Board specific -> see TME of Board chapter “LEMT

functions”

Bit 0-4: Exception Code

Board specific -> see TME of Board chapter “LEMT functions”

STOP

SM-bus stop condition

Table 4.9.2 Explanation of Table 4.9.1