11 power specifications, 12 operating temperatures, 13 environmental – ADLINK cExpress-BL User Manual
Page 9: 14 specification compliance, 15 operating systems, Power specifications, Operating temperatures, Environmental, Specification compliance, Operating systems
cExpress-BL
Page 9
2.11 Power Specifications
¾
Power Modes:
AT and ATX mode (AT mode startup controlled by SEMA Board Controller)
¾
Standard Voltage Input: ATX = 12V±5% / 5Vsb ±5% or AT = 12V±5%
¾
Wide Voltage Input:
ATX = 5~20 V / 5Vsb ±5% or AT = 5 ~20V
¾
Power Management:
ACPI 4.0 compliant, Smart Battery support
¾
Power States:
supports C1-C6, S0, S3, S4, S5 (Wake-on-USB S3/S4, WoL S3/S4/S5)
¾
ECO
mode: supports deep S5 for 5Vsb power saving
2.12 Operating Temperatures
¾
Standard Operating Temperature:
0°C to +60°C (Wide Voltage Input)
¾
Extreme Rugged™ Operating Temperature (optional): -40°C to +85°C (Standard Voltage Input)
2.13 Environmental
¾
Humidity:
5-90%
RH
operating,
non-condensing
5-95% RH storage (and operating with conformal coating).
¾
Shock and Vibration: IEC 60068-2-64 and IEC-60068-2-27
MIL-STD-202F,
Method
213B,
Table
213-I, Condition A and Method 214A, Table 214-I, Condition D
¾
HALT:
Thermal
Stress,
Vibration
Stress, Thermal Shock and Combined Test
2.14 Specification Compliance
¾
PICMG COM.0: Rev 2.1 Type 6, Compact size 95 x 95 mm
2.15 Operating Systems
¾
Standard Support:
Windows 7/8.1u 32/64-bit, Linux 32/64-bit
¾
Extended Support (BSP):
Windows Embedded Standard 7 (WES7), Windows Embedded 8 Standard (WE8S), Linux, VxWorks