5 communications with ipmc, 6 ipmi sensors list, 7 relevant documents – ADLINK CT-61 User Manual
Page 84: Communications with ipmc, Ipmi sensors list, Relevant documents, 6 ipmi sensors list 9.7 relevant documents

74
IPMI User Guide
9.5
Communications with IPMC
Operating systems need to use a serial port to communicate with
the IPMC. The resource setting of the serial port must be IO:
0x3E8 and IRQ: 3. The communication setting of the serial port
must be BaudRate: 9600, DataBit: 8, ParityCheck: None, StopBit:
1, and FlowControl: None. In Windows XP, use “COM3” to com-
municate with the IPMC.
9.6
IPMI Sensors List
9.7
Relevant Documents
Sensor
Number
Sensor name
Normal
Reading
Remark
00h
BMC Watchdog
01h
3.3V
3.3 V
02h
5V
5 V
03h
12V
12 V
04h
SYSTEM Temp
25°C
05h
CPU Temp
40°C
06h
BIOS CHANGE
07h
BIOS POST ERROR
Document Title
Revision
Source
Intelligent Platform
Management Interface
Specification v2.0
Document Revision 1.1
February 20, 2002
http://www.intel.com/design/
servers/ipmi/spec.htm
PICMG 2.9 D1.0
CompactPCI System
Management Specification
January 21, 2000
Intelligent Platform
Management Bus
Communications Protocol
Specification v0.9
Document Revision 0.15
June 24, 1997
Intel Corp.
servers/ipmi/license_ipmi.htm