beautypg.com

Venting installation, Continued – Desa CSDPBN User Manual

Page 18

background image

111739-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

18

Figure 40 - Vertical Venting Configuration Using Two 90° Elbows

VENTING INSTALLATION

Continued

Figure 39 - Vertical Venting Configuration Using Two 90° Elbows
with Two Horizontal Runs

Note: Install restrictor
into 4" (10.16 cm)
collar of burner
system as shown.

Note: Install restrictor
into 4" (10.16 cm)
collar of burner
system as shown.

VENTING INSTALLATION

Installation for Vertical Termination (Cont.)

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H

1

) +

Horizontal (H

2

)

5' min. (1.52 m) 2' max. (0.61 m)
6' min. (1.83 m) 4' max. (1.22 m)
7' min. (2.13 m) 6' max. (1.83 m)
8' min. (2.44 m) 8' max. (2.44 m)

20' max. (6.1 m) 8' max. (2.44 m)

Venting with Two

90° Elbows

Vertical (V

1

)

Horizontal (H)

5' min. (1.52 m)

6' max. (1.83 m)

6' min. (1.83 m) 12' max. (3.66 m)
7' min. (2.13 m) 18' max. (5.49 m)
8' min. (2.44 m)

20' max. (6.1 m)

Note: Vertical (V

1

) +

Vertical (V

2

) = 20' max.

This manual is related to the following products: