15

Figure 33 - Horizontal Termination Configuration for Venting
Using Two 90° Elbows with Termination at 90° with Stove

Figure 31 - Horizontal Termination Configuration for Venting
Using One 90° Elbow

Horizontal Venting

Vertical (V) Horizontal (H)

52" min.

26" max.

(1.32 m)

(.66 m)

63" min.

49" max.

(1.6 m)

(1.24 m)

86" min.

96" max.

(2.18 m)

(2.44 m)

91" min.

20' max.

(2.31 m)

(6.1 m)

Horizontal Termination Configurations

Figures 31 through 33 show different configurations for venting
with horizontal termination. Each figure includes a chart with
vertical minimum/maximum and horizontal maximum dimensions
which must be met. Seal all connections with high temperature
silicone sealant (outer pipe only) as specified in the second warning
statement on page 12. All horizontal piping runs require 1/4" (6.35
mm) rise per 12" (0.3 m) of horizontal run.

Figure 32 - Horizontal Termination Configuration for Venting
Using Two 90° Elbows

VENTING INSTALLATION

Continued

VENTING INSTALLATION

Installation for Horizontal Termination (Cont.)

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H

1

) +

Horizontal (H

2

)

6' min.

(1.83 m)

4' max. (1.22 m)

7' min.

(2.13 m)

6' max.

(1.83 m)

8' min. (2.44 m) 10' max. (3.05 m)

20' max. (6.1 m) 12' max. (3.66 m)

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H

1

)

Horizontal (H

1

) +

Horizontal (H

2

)

6' min. (1.83 m) 4' max. (1.22 m) 8' max. (2.44 m)
7' min. (2.13 m) 6' max. (1.83 m) 12' max. (3.66 m)
8' min. (2.44 m) 8' min. (2.44 m)

20' max. (6.1 m)

20' max. (6.1 m) 8' max. (2.44 m) 20' max. (6.1 m)

This manual is related to the following products: