ADLINK ND-6013 User Manual
Page 100
92
• Data Format and Input Range
The following table shows the relation between the input range setting with the
data format and the resolution when using ND-6011/D or 6018 to measure
temperature by thermocouple.
Code
Input Range
Thermocouple
Data
Format
Maximum Minimum
Displayed
Resolution
0E
J (0
°C to 760°C)
Eng. Units
+760.00
+000.00
0.01
°C
0F
K (0
°C to 1000°C)
Eng. Units
+1000.0
+0000.0
0.1
°C
10
T (-100
°Cto400°C)
Eng. Units
+400.00
-100.00
0.01
°C
11
E (0
°C to 1000°C)
Eng. Units
+1000.0
+0000.0
0.1
°C
12
R (500
°C to 1750°C)
Eng. Units
+1750.0
+0500.0
0.1
°C
13
S (500
°C to 1750°C)
Eng. Units
+1750.0
+0500.0
0.1
°C
14
B (500
°C to 1800°C)
Eng. Units
+1800.0
+0500.0
0.1
°C
15
N (-270
°C to 1300°C)
Eng. Units
+1300.0
-0270.0
0.1
°C
16
C (0
°C to 2320°C)
Eng. Units
+2320.0
+0000.0
0.1
°C
Code
Input Range
Thermocouple
Data
Format
Maximum Minimum
Displayed
Resolution
0E
J (0
°C to 760°C)
% of FSR
+100.00
+000.00
0.01%
0F
K (0
°C to 1000°C)
% of FSR
+100.00
+000.00
0.01%
10
T (-100
°Cto400°C)
% of FSR
+100.00
-025.00
0.01%
11
E (0
°C to 1000°C)
% of FSR
+100.00
+000.00
0.01%
12
R (500
°C to 1750°C)
% of FSR
+100.00
+028.57
0.01%
13
S (500
°C to 1750°C)
% of FSR
+100.00
+028.57
0.01%
14
B (500
°C to 1800°C)
% of FSR
+100.00
+027.27
0.01%
15
N (-270
°C to 1300°C)
% of FSR
+100.00
-020.76
0.01%
16
C (0
°C to 2320°C)
% of FSR
+100.00
+000.00
0.01%
Code
Input Range
Thermocouple
Data
Format
Maximum Minimum
Displayed
Resolution
0E
J (0
°C to 760°C)
2’s Comp.
7FFF
0000
1 LSB
0F
K (0
°C to 1000°C)
2’s Comp.
7FFF
0000
1 LSB
10
T (-100
°Cto400°C)
2’s Comp.
7FFF
E000
1 LSB
11
E (0
°C to 1000°C)
2’s Comp.
7FFF
0000
1 LSB
12
R (500
°C to 1750°C)
2’s Comp.
7FFF
2492
1 LSB
13
S (500
°C to 1750°C)
2’s Comp.
7FFF
2492
1 LSB
14
B (500
°C to 1800°C)
2’s Comp.
7FFF
238E
1 LSB
15
N (-270
°C to 1300°C)
2’s Comp.
7FFF
E56B
1 LSB
16
C (0
°C to 2320°C)
2’s Comp.
7FFF
0000
1 LSB