ADLINK PCI-8124-C User Manual
Page 54

44
TriggerMaster Utility
5. Set Sources:
TRG_# and TTL_# Source: Display the
Set_TRG_&_TTL_Out form to set source, logic and
mode for TRG output and TTL output for TRG_# and
TTL_# output. The related functions are
_8124_set_trigger_source
,
_8124_set_trgOut_logic
, and
_8124_set_ttlOut_source
.
PWM_# Source: Display the Choose_PWM_Source
form to set the source for PWM_#. The related function
is _8124_set_pwm_source.
LCMP Source: Display the Set_Linear_Comparator form
to set each linear comparator. The related functions are
_8124_enable_linear_set
,
_8124_set_linear_compare
, and
_8124_set_linear_source
. Note: the setting in this
form is for all channels.
CNT_#: Display the Set_CNT_Source form to set the
source for counter_#. The related function is
_8124_set_counter_source
.
Set_Timer_# Interval: Set the interval timer. The unit is
millisecond. The related function is _8124_set_Timer.
6. Set FIFO_# data:
5 Points Test: In this area user can set five data into the
FIFO comparator once to verify the functionality of FIFO
compare. The related function is
_8124_set_fifo_array
.
Huge Points Test: In this area user can input a large
number of data into the FIFO comparator. The related
function is _8124_set_fifo_array ().
Note: if FIFO comparator is not selected the source for
the PWM_#, this area is locked.
7. Displays version: Displays the libray, firmware and the
driver version. The related funcion is
_8124_get_version
.