Signal

Connections

PCI-9524

ADLINK Technology Inc.

User’s Manual

Copyright 2008

NOTE:

NOTE:

1) Short AIn+ and AIn- to AGND for unused transducer input
channels
2) Exceeding the maximum input voltage range may perma-
nently degrade performance, or damage the input amplifier.

ISO5VDD ISOGND Output

Isolated 5V output from internal regulator.
Insignificant driving capacity, used for
resistor pull-ups only.

ISOPWR ISOGND Output

Isolated 5V output from internal regulator.

Insignificant driving capacity, used for
resistor pull-ups only. May be modified to

have 12 V output capability.

EXT_ISOPWR ISOGND

Input

Use in conjunction with IDOn and external
power supply, to provide current return
path for fly-wheel diodes.

ISOGND --

--

Isolated

digital

ground.

NC --------

--------