Table 1-5, Settling time to full scale step – ADLINK DAQe-2214 User Manual
Page 18

6
Introduction
X
Settling time to full-scale step (Typical, 25°C):
X
Time-base source: Internal 40 MHz or external clock Input
(f
max
: 40 MHz, f
min
: 1 MHz, 50% duty cycle)
X
Trigger modes: Post-trigger, delay-trigger, pre-trigger and
middle-trigger
X
Offset error:
Z
Before calibration: ±60 mV max
Z
After calibration: ±1 mV max
X
Gain error (relative to calibration reference):
Z
Before calibration: 0.06% of output max
Z
After calibration: 0.01% of output max
Input Range
Condition
Settling time
All Ranges
• Multiple channels,
multiple ranges.
• All samples in unipolar/
bipolar mode.
4 µs to 0.01% error
All Ranges
• Multiple channels,
multiple ranges.
• All samples in unipolar
and/or bipolar mode.
4 µs to 0.01% error
Table 1-5: Settling Time to Full Scale Step