beautypg.com

5e - sensor faults, 5f - tamper faults, 5g - system not ready – DSC WLS900 User Manual

Page 9: 5h - no response from controller

background image

9

5E - Sensor Faults

This message will only be displayed if “Sensor Faults

Sensor Faults

Sensor Faults

Sensor Faults

Sensor Faults” are detected. A

Sensor Fault may mean that a Sensor’s batteries are running low, or that the
Sensor is unable to communicate with the Controller. This message will be
displayed before scrolling to the next message.

Press the

-YES Key to view the list of “Sensor Faults

Sensor Faults

Sensor Faults

Sensor Faults

Sensor Faults”. Use the

-YES

Key to scroll through the list of Sensor Faults. Check the Sensors indicated
to ensure that their batteries are installed properly. If you require assistance,
or if Sensor Faults occur often, contact your installer.

5F - Tamper Faults

This message will only be displayed if the system detects a Tamper
condition. An open Tamper condition may indicate that a component has
been removed from its normal location, or has been interfered with. This
message will be displayed before scrolling to the next message.

Press the

-YES Key to view the list of “Tamper Faults

Tamper Faults

Tamper Faults

Tamper Faults

Tamper Faults”. Use the

-YES

Key to scroll through the list of Tamper Faults. When finished viewing the list
of Tamper Faults, press the

-NO Key. Check the components indicated to

ensure that they are mounted properly. If you require assistance, contact your
installer.

5G - System Not Ready

This message will only appear if the system is not ready to be armed
because one or more zones are open. A zone is “open”, if, for example, a
protected Door or Window is improperly secured. Zones will be indicated
as “open” if they have a Tamper or Sensor Fault. Refer to the Tamper Fault
in Section 5F or Sensor Fault in Section 5E for information on viewing these
conditions. This message will be displayed automatically.

Press the

-YES Key to view the list of Open Zones; press the

-YES Key

again to scroll through the list of Open Zones. When finished reviewing the
list, press the

-NO Key to return to the “View Open Zones Y/N?” message.

With this message displayed, press the

-NO Key to display the next

message.

To bypass zones, press the

-YES Key. To continue without bypassing

zones, press the

-NO Key. For instructions on bypassing zones, refer to

Bypassing Zones, Section 6.

5H - No Response From Controller

This message will be displayed if the Keypad is unable to communicate with
the Controller. This message will be displayed and, then the Keypad will
return to its inactive state. If the Keypad displays this message often:

• ensure the Controller’s adaptor is properly connected and plugged in
• ensure the Keypad’s batteries are not reporting “Low Battery” and are

properly installed

• if you require assistance, contact your installer.