beautypg.com

Delta Electronics 1Phase CliQ II DIN Rail DRP024V060W1BA User Manual

Page 3

background image

Switch Mode Power Supply DRP024V060W1BA


3/13

Rev: 00,

1/10/2011















General Data

Isolation voltage:
Input / output type test/routine test
Input / PE type test/routine test
output / PE type test/routine test


4 KVAC / 3 KVAC
1.5 KVAC / 1.5 KVAC
1.5 KVAC / 500 VAC

Degree of protection

IP20

Class of protection

Class I with PE connection

MTBF

> 1,000,000hrs.

Type of housing

Aluminium (AI5052)

Dimensions (L / W / H )

121mmx32mmx125mm

Weight

0.37Kg

STATUS Indicator

LED (6) DC OUTPUT OK

YES (GREEN LED)

Climatic Data

Ambient temperature (Operating)
Ambient temperature (Storage)

-20°C to 80°C (> 50°C de-rating)
-25°C to 85°C

Humidity at 25°C, non-condensing

< 95% RH

Vibration (Non-Operating)

10Hz to 500Hz @ 30 m/ S

2

(3G peak); displacement of 0.35mm;

60min per axis for all X, Y, Z direction. in acc. with IEC 68000-2-6.

Shock (in all directions)

30G (300m/S

2

) in all directions according to IEC60068-2-27

Pollution degree

2 according to EN50178

Climatic class

3K3 according to EN 60721

In conformance with EMC guideline 89/336/EEC and low
voltage directive 73/23/EEC
EMC (electromagnetic compatibility)

DINRAIL 1AC / 24V DC / 2.5A (EOE11010248)

Immunity to interference according to EN 61000-6-2

EN 61000-4-2

1)

Housing

Discharge of static electricity (ESD) Contact discharge:
Air Discharge:


LEVEL 4
8 KV
15 KV

EN 61000-4-3

1)

Housing

Radiate Field Immunity Frequency/Field intensity:

LEVEL 3
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation

EN 61000-4-4

1)

Fast transients (Burst):

2KV

4)

EN 61000-4-5

1)

Surge voltage Immunity (Surge):

2KV

3)

/ 2KV

4)

(Level 3)


EN 61000-4-6

1)

I/O:

Conducted Immunity Frequency / U

o

:

Level 3
0.15MHz - 80MHz / 10Vrms.

EN 61000-4-11

2)

Voltage dips

Input: Main Buffering > 20ms.

Noise emission according to EN 61000-6-3

Emitted radio interface

Radio interference voltage


EN55011 (EN55022) CLASS B

5

EN55011 (EN55022) CLASS B

5

EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EN 61000 corresponds to IEC 61000
1) Criterion A: Normal operating behavior within the defined limits.
2) Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
5) Class B: Area of application industry and residential.