beautypg.com

Troubleshooting – Desa VSGF28NTE User Manual

Page 23

background image

www.desatech.com

113135-01A

23

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Turning control knob to HI

position when burners are cold

2. Air in gas line

3. Air passageways on fireplace

blocked

4. Dirty or partially clogged

burner orifice(s)

1. When heated, vapors from fur-

niture polish, wax, carpet
cleaners, etc. may turn into
white powder residue

1. Improper log placement

2. Drafts or other air currents af-

fecting flame pattern

3. Air holes at burner inlet

blocked

4. Burner flame holes blocked

1. Metal expanding while heat-

ing or contracting while
cooling

REMEDY

1. Turn control knob to LO po-

sition and let warm up for a
minute

2. Operate burners until air is re-

moved from line. Have gas
line checked by local natural
or propane/LP gas company

3. Observe minimum installation

clearances (see pages 10
through 12)

4. Clean burners (see Cleaning

and Maintenance, page 20) or
replace burner orifice(s)

1. Turn heater off when using

furniture polish, wax, carpet
cleaners, or similar products

1. Properly locate logs (see In-

stalling Logs, page 16)

2. Eliminate source of drafts

around heater

3. Clean out air holes at burner

inlet. Periodically repeat as
needed

4. Remove blockage

1. This is common with most

fireplaces. If noise is exces-
sive, contact qualified service
person

OBSERVED PROBLEM

Fireplace produces a whistling
noise when burners are lit

White powder residue forming
within burner box or on adja-
cent walls or furniture

Dark residue on logs or inside of
fireplace
Note:

After removing all causes

of residue deposits, completely
clean fireplace and appliance
of all residue before reusing
appliance

Fireplace produces a clicking/
ticking noise just after burners
are lit or shut off

This manual is related to the following products: