beautypg.com

Troubleshooting – Desa VSGF28NTE User Manual

Page 22

background image

www.desatech.com

113135-01A

22

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Control knob not fully pressed in
2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Thermocouple connection

loose at control valve

5. Pilot flame not touching ther-

mocouple, which allows ther-
mocouple to cool, causing pi-
lot flame to go out. This prob-
lem could be caused by one or
both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot

6. Thermocouple damaged
7. Control valve damaged
8. On thermostat models, safety

interlock system has been trig-
gered

1. Burner orifice(s) clogged

2. Inlet gas pressure is too low

3. Mislocated crossover tube

1. Manifold pressure is too low

2. Burner orifice(s) clogged

3. Mislocated crossover tube

1. Burner orifice is clogged or

damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

1. Residues from manufacturing

processes and logs curing

REMEDY

1. Press in control knob fully
2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Fully open equipment shutoff

valve

4. Hand tighten until snug, then

tighten 1/4 turn more

5. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 20) or replace ODS/pi-
lot assembly

6. Replace pilot assembly
7. Replace control valve
8. Wait one minute for safety in-

terlock system to reset. Repeat
ignition operation

1. Clean burner(s) (see Cleaning

and Maintenance, page 20) or
replace burner orifice(s)

2. Contact local natural or pro-

pane/LP gas company

3. Contact qualified service person

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 20) or
replace burner orifice(s)

3. Contact qualified service person

1. Clean burner (see Cleaning

and Maintenance, page 20) or
replace burner orifice

2. Replace damaged burner
3. Replace gas regulator

1. Check burner(s) for dirt and

debris. If found, clean
burner(s) (see Cleaning and
Maintenance
, page 20)

2. Replace gas regulator

1. Problem will stop after a few

hours of operation

OBSERVED PROBLEM

ODS/pilot lights but flame goes
out when control knob is re-
leased

One or both burners do not light
after ODS/pilot is lit

Delayed ignition of one or both
burners

Burner backfiring during com-
bustion

Yellow flame in front burner
during burner combustion

Slight smoke or odor during ini-
tial operation

This manual is related to the following products: