Creating Labels Using Internal Batch Software
42
Allegro2
Notice in the upper left-hand corner of the screen that the current
Field Number is displayed. This program can accommodate up to
200 fields per format. Use the return key or the arrow keys to move
the cursor around within the 200 fields, one field at a time. A sample
label format is illustrated in Figure 3-4. To create a label, press the
F1 key to return to the Create/Modify Label Screen. The cursor will
be in the Label Name Position.
CREATE/MODIFY LABEL
MODULE NAME: ________________
LABEL NAME: ________________
ROT
FNT
XW
XH
BH
ROW
COL
TYPE
DATA/PROMPT
---
---
--
--
----
----
----
-----
--------------------------
1
2
2
2
0.00
03.70
00.20
D
NYLON INSULATED TOGGLE SWITCH
1
X
1
1
0.00
03.60
00.10
D
B370040003003
1
6
2
2
0.00
00.30
00.20
D
DA100-PB-B
1
X
1
1
0.00
00.20
00.15
D
L400080
1
Y
1
1
0.00
01.50
02.85
D
SW5
1
a
6
2
0.40
01.35
00.15
D
DA100 PB B
1
1
2
2
0.00
01.20
00.65
D
DA100 PB B
1
3
1
1
0.00
03.20
00.20
D
SWITCH ACTION
1
1
2
2
0.00
03.00
00.20
D
SPST on-None-OFF
1
3
1
1
0.00
02.70
00.20
D
TERMINALS
1
1
2
2
0.00
02.50
00.20
D
SOLDER/SPADE
1
3
1
1
0.00
02.20
00.20
D
RATING
1
1
2
2
0.00
02.00
00.20
D
@ 10 AMPS, 125VAC
1
X
1
1
0.00
01.90
00.10
D
B200160003003
1
X
1
1
0.00
02.40
00.13
D
L194003
1
X
1
1
0.00
02.90
00.13
D
L194003
1
0
1
1
0.00
00.00
00.15
D
ALLEGRO2 LABEL PRINTER
Figure 3-4 Sample Label Format
3. Enter an alphanumeric name of up to 16 characters for this
label, followed by the return key. The message "New Label
Format?" appears. Answer Y or N. If yes, the cursor moves
to the ROT position. If the cursor does not move past the
New Label Format position, the memory module 's Write
Protect Switch is ‘on’; turn it ‘off’ to continue.