Troubleshooting Chart (Continued)

Possible Cause(s)

Corrective Action

Symptom

Heater ignites, but flameout control
shuts off heater after a short period of
time (Continued)

4. Clean photocell lens with clean,

cotton swab

5. Replace photocell

6. Replace flameout control

7. Replace fan switch

4. Dirty photocell lens

5. Open or damaged photocell

6. Bad flameout control

7. Damaged fan switch

Heater burns, but puffs of smoke can
be seen

Heater does not burn steady

Heater burns with odor

Adjust pump pressure (See Pump
Pressure Adjustment sections on page 10)

Add fuel to tank

Check fuel tank for bubbles of water in
bottom. If found, remove fuel (See
Storing, Transporting, or Shipping,
page 11). Clean tank and fuel filters
(See Fuel Filters, page 7). Fill with clean
fuel

1. Remove wrong fuel (See Storing,

Transporting, or Shipping, page 11).
Clean tank and fuel filters (See Fuel
Filters
, page 7). Fill with correct fuel

2. Clean fuel filters (See Fuel Filters,

page 7)

3. Tighten all fuel line connections (See

Fuel Lines, page 7)

4. Replace nozzle (See Nozzle, page 9)

5. Check voltage at heater. Voltage at

heater should be not less than 90%
of rated voltage (108V minimum for
120V heaters)

6. Check and tighten all fuel line

connections (See Fuel Lines, page 9)

Wrong pump pressure

Heater almost out of fuel

Water condensation in fuel tank

1. Wrong fuel

2. Dirty fuel filters

3. Air leak in suction system

4. Dirty nozzle

5. Low voltage causing motor to

operate below rated speed

6. Loose fuel line

Heater smokes continuously