Initial start-up – Carrier Miracool User Manual

Page 7

background image

7

TABLE 2 – UNIT DATA

UNIT MC2000H

/

MC2000S

Voltage (V)

Nominal 115
Range 105-125

Frequency (Hz)

60

Total Amps

11.3

Refrigerant Type

R-134A

Charge Amount (oz)

19.4

Design Pressure (psig)

High Side

220

Low Side

88

INITIAL START-UP

POWER SUPPLY

Connect unit to power supply. Check to verify that
the compressor, lamp and fans are running.

Important: Low line voltage is often the cause of
service complaints. Check to see that the line
voltage is within specified range with the unit
running.

TEMPERATURE CONTROL

The temperature control knob is located inside the
cabinet in the motors panel. See Figure 8. Unit is
factory set at the number 4 position (normal),
which will maintain the product at approximately
38F. For colder temperature, turn the black
adjustment knob to a higher setting. Adjust
temperature control in small increments, one
position at a time.

U

CAUTION

Allow 24 hours between temperature control
adjustments. Excessive tampering with
temperature control could lead to service
difficulties.

NOTE: For operation above 3,000-ft altitude,
thermostat should be adjusted by a qualified
service technician.

FIGURE 8 – TEMPERATURE CONTROL KNOB

TEMPERATURE
CONTROL KNOB