beautypg.com

Cooper Lighting VT2 User Manual

Page 2

background image

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

09/29/2008 10:06:07 AM

Specifications and Dimensions subject to change without notice.

ADF071394

PHOTOMETRICS

ORDERING INFORMATION

ACCESSORIES

SHIPPING DATA

VT2

C o e ffi c i e n t s o f U t i l i z a t i o n

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

10%

0%

rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

RCR

0
1
2
3
4
5
6
7
8
9

10

L u m i n a n c e Da t a

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

7779

10632

11288

55

7074

10221

10954

65

6110

9764

12196

75

5205

13928

20408

85

4251

27797

39527

Z o n a l L u m e n S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-180

||

?

C a n d l e p o we r

Angle

Along II

45°

Across ?

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

VT2-254DR-UNV-
EB81-WL-M4-U
Electronic Ballast
(2) F54/T5/835 Lamps
4460 Lumens each
Spacing criterion:
(II) 1.2 x mounting
height, (? ) 1.6 x
mounting height
Efficiency 74.3%
Test Report:
127P111
LER = FI57
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.24

1615

1615

1615

1613

1632

1648

1592

1673

1723

1556

1704

1781

1504

1717

1820

1438

1712

1839

1357

1683

1815

1262

1625

1743

1154

1532

1635

1033

1412

1499

902

1263

1355

762

1101

1180

621

944

994

485

775

968

362

667

1051

253

677

992

158

612

827

74

455

647

26

297

463

87 87 87 87

85 85 85 85

80 80 80

76 76 76

72 72 72

70

78 73 70 66

75 71 68 65

67 64 62

64 61 59

60 59 57

55

70 63 57 52

68 61 56 51

58 53 50

55 51 48

52 49 46

44

64 55 48 43

61 53 47 42

51 45 41

48 43 40

45 42 39

37

58 48 41 36

56 47 40 35

45 39 34

42 38 34

40 36 33

31

53 43 36 31

51 42 35 30

40 34 30

38 33 29

36 32 28

26

49 39 32 27

47 38 31 26

36 30 26

34 29 25

33 28 25

23

45 35 28 23

44 34 28 23

32 27 23

31 26 22

30 25 22

20

42 32 25 21

41 31 25 20

30 24 20

28 23 20

27 23 19

18

39 29 23 18

38 28 22 18

27 22 18

26 21 18

25 21 17

16

37 27 21 17

36 26 20 16

25 20 16

24 19 16

23 19 16

14

1411

15.8

21.3

2397

26.9

36.2

4380

49.1

66.2

6268

70.3

94.8

6614

74.2

100.0

C o e ffi c i e n t s o f U t i l i z a t i o n

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

10%

0%

rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

RCR

0
1
2
3
4
5
6
7
8
9

10

L u m i n a n c e Da t a

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

4874

6095

5343

55

4392

5171

4906

65

3669

4791

5995

75

2853

5921

5721

85

1868

5874

5512

Z o n a l L u m e n S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-180

||

?

C a n d l e p o we r

Angle

Along II

45°

Across ?

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

VT2-232DR-UNV-
EB81-WL-M4-U
Electronic Ballast
(2) T8 Lamps
2850 Lumens each
Spacing criterion:
(II) 1.3 x mounting
height, (? ) 1.6 x
mounting height
Efficiency 81.7%
Test Report:
127P113
LER = FI71
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.39

1036

1036

1036

1036

1059

1077

1023

1114

1175

1000

1175

1275

968

1227

1344

926

1255

1352

876

1245

1284

817

1184

1182

750

1080

1070

674

961

946

591

834

833

501

706

780

408

597

785

317

533

816

233

520

755

160

489

624

97

396

518

45

302

434

16

224

353

96 96 96 96

93 93 93 93

87 87 87

82 82 82

78 78 78

76

86 81 77 73

83 78 74 71

74 70 68

69 67 64

65 63 61

59

77 69 63 58

74 67 61 57

63 58 54

60 56 52

56 53 50

48

70 60 53 47

67 59 52 46

55 49 45

52 47 43

49 45 42

40

64 53 45 40

61 52 44 39

49 43 38

46 41 37

44 39 35

33

58 47 39 34

56 46 39 33

44 37 32

41 36 31

39 34 31

29

54 42 35 29

52 41 34 29

39 33 28

37 32 27

35 30 27

25

50 38 31 26

48 37 30 25

35 29 25

34 28 24

32 27 24

22

46 35 28 23

45 34 27 22

32 26 22

31 25 21

29 25 21

19

43 32 25 20

42 31 25 20

30 24 20

28 23 19

27 22 19

17

40 29 23 18

39 29 22 18

27 22 18

26 21 17

25 20 17

15

985

17.3

21.1

1675

29.4

36.0

2999

52.6

64.4

4316

75.7

92.7

4658

81.7

100.0

Width
Blank
=4' Length
8T=8' Length

Series

VT2=Vapor-Tite

Number of Lamps

(3)

1=1 lamp (T5 or T8)

2=2 lamps (T5 or T8)

3=3 lamps (T8 only)

(Lamps not included)

Lamp Type

32=32W T8 Lamp (4' Long)

54T5=54W T5HO Lamp (4' Long)

Lens
DR
=Internal Prismatic Lens/15% DR High Impact Additive (Standard)
DR-100%=100% High Impact Additive
LEX=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern

Voltage

(1)

120V=120 Volt

277V=277 Volt

347V=347 Volt

480V=480 Volt

UNV=Universal

Voltage 120/277V

UNC=Universal

Voltage 347/480V

(T5 Linear Only)

Fusing
GL
=Single Element Fuse
GM=Double Element Fuse
Emergency=EM Installed,

see EM options table

(3) (4)

NOTES:

(1)

Ballast type used only if ballast & voltage is chosen

(2)

Not available when specify-

ing emergencies, voltage must be specific.

(3)

T5HO is only available in 1 or 2-lamp versions

only.

(4)

Emergency option in 3 lamp version must use remote mount test switch.

Options
RIF1
=Radio

Interference Suppressor
TH=(2) Top Watertite Hubs
TEH=(2) Top & (2) End Watertite

Hubs (all Watertite Hubs have 1/2"
Conduit Entry)
TILW=Tandem In-Line Wiring

Option (Consult TILW Option Catalog Page)
PI/CPI=Plug-In Option
DD=Deep Diffuser (4' Length)

M4=Specular Reflector
SSL=Stainless Steel Latches

Packaging
U
=Unit Pack
PALC=Job

Pack in Carton

Ballast Type

(1)

T8 Systems
EB8
=T8 Electronic Instant Start.

(4)

Total Harmonic Distortion < 20%

EB8 /PLUS=T8 Electronic Instant Start.

High Ballast Factor >1.13. Total

Harmonic Distortion < 20%

ER8 =T8 Electronic Program Rapid Start.

Total Harmonic Distortion < 10%

ER8 /PLUS=T8 Electronic Program Start.

High Ballast Factor >1.13. Total

Harmonic Distortion < 10%

EB8 /L= T8 Electronic Instant Start w/0.80

Ballast Factor.

T5 Systems
EBT
=T5HO Electronic Program Start.

No. of Ballast

1 or 2

No. of

Ballast

1 or 2

No. of Ballast

1 or 2

No. of Ballast

1 or 2

No. of Ballast

1 or 2

WL=Wet

Location

Label

(Available for 4' Fixture Length) To Complement
Deep Diffuser Depth of 8' Fixture

No. of

Ballast

1 or 2

S A M P L E N U M B E R : 8 T V T 2 - 2 5 4 D R - U N V- E B 8 2 - M 4 - U

Accessories (order separately)

VT2-Chain/Set-U=Chain Hanging Set

Includes 6 ft. of chain, 4 large
S-Hooks and 4 small S-Hooks
Order One (1) Kit for each
2' or 4' Fixture
Two (2) Kits Recommended
For 8' Fixture
VT2-SS-MBK=Stainless

Steel Mounting Bracket

VT2-132DR-WL

35 lbs.

VT2-232DR-WL

35 lbs.

Catalog No.

Wt.