...Installation - Steps...
STEP 4
CONNECT TO ELECTRICAL SUPPLY
Remove screw securing the cable
clamp and lift up clamp
From the arrowed positions shown in
figure 5, prise open the cover using a
flat bladed screwdriver
Feed the cable through the cable clamp
and make the connection to the terminal
block.
Note - ensure the correct connection
of the cable as shown in figure 6.
Refit the terminal block cover and
secure the mains cable securely with
the cable clamp.
STEP 5 SECURE TO CABINET
•
Raise appliance onto the cabinet base and
slide Into position making sure the cable
does not become trapped or kinked.
•
Using four chipboard screws (not
supplied) secure the appliance to the
side edges of the cabinet (positions
arrowed in figure 7).
•
Note - If the cabinet is not made of a
high quality material then use the four
cabinet fixing plates provided to secure
the appliance to the cabinet.
•
Replace the oven and grill doors by
reversing the removal order, and turn
locking disc anti-clockwise to the
normal position as shown in figure 8.
Replace oven door inner glass making
sure text THIS SURFACE MUST BE
NEAREST FACE TO THE OVEN is
legible.
Figure 5 opening terminai block cover
Figure 7 location of securing holes
Figure 8 hinge normal unlocked position