beautypg.com

Quick start, Install / service menus, Equipment summary – Carrier Infinity SYSTXCCUID01- B  User Manual

Page 7: Static pressure check, Set day, time & desired humidity, Override heating schedule, Quick program schedule for all days

background image

7

UV Lights Installed
This screen will appear to select whether UV lights are installed on

the system, select YES or NO, then press right--side button to
continue.

Equipment Summary

EQUIPMENT SUMMARY

FURNACE

58MVB0100-12

AC

24ANA136A003

FILTER

EAC

HUMIDIFIER

YES

UV LIGHTS

YES

NO YES

SETUP

COMPLETE!

SAVE

ALL SELECTIONS/

NO YES

A07247

Fig. 20 -- Equipment Summary

The “EQUIPMENT SUMMARY” screen will appear after
Accessories have been selected. This screen will give a summary of

all equipment automatically found or manually selected. If a wrong
selection was made, press left--side button (BACK selection) to go

back to that particular screen and make changes. When everything

is OK, press right--side button again to continue. (See Fig. 20.)
The “SETUP COMPLETE! SAVE ALL SELECTIONS?” screen

will appear after Equipment Summary. To Save All Selections
press (YES) right--side button. Pressing the left--side button (NO

selection) will return to the Equipment Summary screen where
changes can be performed to any of the equipment selection

screens. After selecting YES, the initial power up sequence of the

new Infinity Control is complete.

Static Pressure Check

STATIC

PRESSURE

CHECK

PLEASE WAIT

EXTERNAL STATIC

PRESSURE

MEASURED:

0.72 INCHES

AT 1200 CFM

CONTINUE >

A05000

Fig. 21 -- Static Pressure Check

This screen will appear after Setup is exited. The system will

perform a static pressure check. This process will take about 1 1/2
minutes to complete. When completed, a screen will appear

displaying the static pressure (in inches) across the equipment at
the expected highest delivered airflow. If the static pressure is over

1 inch, a warning will appear, but equipment operation and the

TrueSenset dirty filter detection operation will not be affected.
NOTE: The static pressure check occurs only at initial installation,
or when INSTALL is run in the INSTALL/SERVICE menu.

QUICK START

For first time installers, Quick Start will allow a quick start up of
the Infinity System before learning all the details of system

operation. However, for the best possible comfort and operation
refer to the Infinity Control Owner’s Manual.

Set Day, Time & Desired Humidity

1. Flip down the door at the base of the Infinity Control and

press the BASIC button.

2. Adjust the highlighted HOUR setting using the TIME

(+/--) button.

3. Press SCROLL button (down) to highlight MINUTE.
4. Adjust the MINUTE setting using the TIME (+/--) button.

5. Press SCROLL button (down) to highlight DAY.
6. Adjust the current DAY setting using the TIME (+/--) but-

ton.

7. Press SCROLL button (down) to highlight HUMIDITY.
8. Press the red HEAT button to select heating humidity.
9. Adjust desired heating humidity level using either (+/--) but-

ton.

10. Press the blue COOL button to select cooling humidity.
11. Adjust the desired cooling humidity level using ei-

ther(+/--)button.

12. To exit press BASIC button or close door.
13. If changes are made, you will be asked to “SAVE

CHANGES? YES/NO.”

Override Heating Schedule

1. Press the red HEAT button. Heating mode is confirmed

when the red LED next to the red HEAT button is lit.

2. Use the TEMP (+/--) button to select your desired heating

temperature.

3. The default time for temporarily overriding the temperature

schedule is 2:00 HRS as indicated by the text on the lower

left.

NOTE: Override time will not appear if programming has been
turned off.

4. You can change the temporary override time in 15--minute

increments by pressing the TIME (+/--) button until the de-

sired override time is selected, or press the HOLD button
anytime to override the schedule indefinitely.

Quick Program Schedule For All Days

This section will give you a quick program schedule for ALL

DAYS of the week. For more information on how to create

customized schedules for every day, the entire week, or weekend,
refer to the Owner’s Manual.

1. Flip down the door at the bottom of the control.
2. Press the SCHEDULE button, which allows you to create

one schedule for the entire home.

3. Press either the LEFT or RIGHT side button repeatedly (if

necessary) until “ALLDAYS” is displayed. The WAKE

time period will be highlighted.

4. Using the TIME (+/.) button, set the start time for this time

period.

5. Press the red HEAT button. Heating temperature will begin

flashing.

6. Set the heating temperature using the TEMP (+/.) button.
7. Press the blue COOL button. Cooling temperature will be-

gin flashing.

8. Set the cooling temperature using the TEMP (+/.) button.
9. Set the remaining periods by using the SCROLL button to

select “DAY”, “EVENING”, and “SLEEP”.

10. Exit the scheduling mode by either closing the door or

pressing the SCHEDULE button.

11. If changes are made, you will be asked to “SAVE

CHANGES YES/NO.

INSTALL / SERVICE MENUS

The “INSTALL / SERVICE” menus contain a set of vital
information. This information enables the Installer or Service

person to view a summary of what has been installed, etc. This

information is not covered in the Owner’s Manual.
To enter INSTALL / SERVICE menus, press and hold the

ADVANCED button for at least ten seconds. The following menu
will appear (See Fig. 22):

CCUI

D

01

--

B