beautypg.com

Selecting outdoor unit, Selecting electric heater, Hydronic heat applications – Carrier Infinity SYSTXCCUID01- B  User Manual

Page 6: Selecting accessories, Ccui d 01 -- b

background image

6

Installer will be asked to select Accessories. Packaged Products
will be automatically identified and the Installer will be asked to

select Accessories. Proceed to Selecting Accessories.
NOTE: If the variable--speed indoor equipment (furnace or fan
coil) cannot be found, the User Interface will display “CANNOT
COMMUNICATE WITH INDOOR UNIT”. This MUST be
corrected before the initial power up sequence can continue. If
indoor unit is found, but outdoor unit is not found, “OUTDOOR
UNIT NOT IDENTIFIED” will appear. Proceed to the next section
for Outdoor Unit Identification.

Selecting Outdoor Unit

OUTDOOR UNIT

NOT IDENTIFIED

SELECT TYPE:

NONE

NONE, AC, HP

PRESS +/- TO MAKE

SELECTION

CONTINUE

OUTDOOR UNIT

ENTER HEAT PUMP

SIZE

36000 BTU

18000 TO 60000 BTU

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

OUTDOOR UNIT

HEAT PUMP

ENTER NUMBER OF

SPEEDS, 1 or 2:

1

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

A03196

Fig. 17 -- Selecting Outdoor Unit

If there is no communicating outdoor unit, the screen, shown in

Fig. 17, will appear. Press either Time or Temp +/-- buttons to
select AC (air conditioner), HP (heat pump), or None (no unit

installed). Press right--side button to continue to next screen.
If either AC or HP has been selected as the outdoor unit type, the

middle screen will appear (see Fig. 17). Press either Time or Temp

+/-- buttons to select appropriate BTU size of outdoor unit, then
press right side button to continue. If a NIM (Network Interface

Module) is applied for non--communicating two--stage outdoor
equipment, select 1 or 2--stage compressor operation, and press

right--side button to continue.
NOTE: Range of outdoor unit BTU selection is limited by model
number of indoor unit installed. The Infinity Control will not allow
an outdoor unit size that is not supported by the installed indoor
unit.
NOTE: On new system installations, the model and serial number
will be recognized and displayed. On any indoor/outdoor board
replacements, the equipment will be recognized but the exact
model/serial number will not be displayed.

Selecting Electric Heater

ELECTRIC HEATER

NOT IDENTIFIED

ENTER SIZE:

5 KW

NONE, 5,10,15 KW

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

A03197

Fig. 18 -- Selecting Electric Heater

If the equipment is a fan coil, packaged heat pump, or packaged

AC and the electric heater is not self--identifying, “ELECTRIC
HEATER NOT IDENTIFIED” will appear (see Fig. 18). Press

either Time or Temp +/-- buttons to select appropriate size of
electric heater installed, then press right--side button to continue.

An asterisks (*) will appear next to electric heater sizes that may
cause excessive airflow.
NOTE: Range of electric heaters available is limited by model
number of the equipment installed. The Infinity Control will not
allow an electric heater size that is not supported by the installed
equipment.

Hydronic Heat Applications

The --B non--zoned model of the Infinity Control supports 2 types

of Hydronic Heat applications:

1. Hot water coil in combination with an FE fan coil and heat

pump, or hot water coil as sole heat source with an FE fan
coil.

2. Non--zoned FE fan coil combined with radiant hot water

heat.

In either application, a Hydronic Heat kit should be installed in
place of an electric heater. See FE fan coil Product Data for

accessory part number. The system will identify that Hydonic Heat
has been installed during the initial commissioning process. The

system will treat the hot water coil as either auxiliary heat in a heat
pump application, or the sole heat source. Setup options for

Hydronic Heat applications are described in the Setup section of

this instruction.

Selecting Accessories

ACCESSORIES

HUMIDIFIER

INSTALLED?

YES

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

ACCESSORIES

U.V. LIGHTS

INSTALLED?

YES

PRESS +/- TO MAKE

SELECTION

BACK CONTINUE

ACCESSORIES

AIR FILTER TYPE:

EAC

EAC

MEDIA

MEDIA + EAC

PRESS +/- TO MAKE

SELECTION

CONTINUE

AIR FILTER MEDIA TYPE

HUMIDIFIER INSTALLED?

U.V. LIGHTS INSTALLED?

A03198

Fig. 19 -- Accessories —UV Lights

Once the indoor and outdoor equipment have been found or
entered, the following screens will appear allowing the Installer to

select the “AIR FILTER TYPE; HUMIDIFIER INSTALLED”;
and “UV LIGHTS INSTALLED” (See Fig. 19). Use either Time or

Temp +/-- buttons to make appropriate selections in the highlighted
area on the display screen. Press right--side button to continue (or

advance) to the next screen.
Air Filter Type
This accessory screen will appear first. The installer will need to

enter the type of filter (MEDIA, EAC, or both). See Table 1 and
make a selection using Time or Temp +/-- button, then press

right--side button to continue.

Table 1 – Filter Selection

INSTALLED FILTER

MENU

SELECTION

1 inch to 4 inch media

MEDIA

High voltage EAC

EAC

High voltage EAC + 1 to 4 inch media

MEDIA + EAC

Infinity Air Purifier

MEDIA

Humidifier Installed
This will appear after the Air Filter Type screen. Select whether a

humidifier is installed on the system, YES or NO, then press
right--side button to continue.

CCUI

D

01

--

B