Figure, Log splitter, Before starting engine – MTD 241-645A User Manual
Page 6
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

;
♦
DEXPOINi
TRAWSIVIIi»:
FLUID
FUNNEL
BREATHER
TUBE
.........
FIGURE 6
FIGURE?
A
CAUTION
You must not operate log splitter
without proper amount of oil in
reservoir tank. (Beam)
4.
Remove the breather plug from breather tube.
See figure 7. Pour approximately 3 gallons of
Dexron automatic transmission fluid ONLY into
breather tube.
Above 32° use SAE 30; below 32° use SAE 10W.
These recommendations must be followed for best
performance and long life.
Change oil first two (2i hours of operation and
check qil level every five (5) operating hours or
each time equipment is used.
Change oil every twenty-five (25) operating hours
or sooner if equipment is operated in extremely
'dusty or dirty conditions.
LOG SPLITTER:
The oil in the reservoir should be changed every (100)
hours of operation.
BEFORE STARTING ENGINE:
During initial break-in period, oil level should be
watched closely. See ENGINE MANUAL.
Use MS classification oil. Do not use oils marked
only MM or ML or unmarked.
NOTE
Carburetors are preset at the factory.
DO NOT attempt to make adjustments
at
this
time.
See
carburetor
instructions
outlined
under
CAR
BURETOR ADJUSTMENT in Engine
Manual.