CITIZEN CT-S651 User Manual
Page 46
— 42 —
Notes:
*1: If print data is very dense, the print head is hot, data transmission is slow, or some other
conditions, the motor and printing may occasionally stop which causes white stripes in the
printout. To print high-density data, set MSW2-3 (Spool Print) to ON to reduce striping, although
this increases the time before printing starts.
For a serial interface, increase the transmission speed to prevent the motor from stopping.
*2: The values for memory switches MSW7-X are only effective when DIP switch no. 1 is set to OFF.
MSW6-1
Act. For Driver
Invalid
Valid
MSW6-2
Character Space
Invalid
Valid
MSW6-3
Reserved
Fixed
—
MSW6-4
Reserved
Fixed
—
MSW6-5
Reserved
Fixed
—
MSW6-6
Reserved
Fixed
—
MSW6-7
Reserved
Fixed
—
MSW6-8
Reserved
Fixed
—
Switch no.
Function
Initial setting
Setting value
*2
MSW7-1
Baud Rate
9600 bps
1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 bps,
38400 bps, 57600 bps, 115200 bps
*2
MSW7-2
Data Length
8bits
7bits, 8bits
*2
MSW7-3
Stop Bit
1bit
1bit, 2bits
*2
MSW7-4
Parity
NONE
NONE, EVEN, ODD
*2
MSW7-5
Flow Control
DTR/DSR
DTR/DSR, XON/XOFF
*2
MSW7-6
DMA Control
Valid
Valid, Invalid
*2
MSW7-7
VCom Protocol
PC Setting
PC Setting, DTR/DSR, XON/XOFF
MSW8-1
Print Width
576dots
(3-inch type)
384dots
(2-inch type)
640dots, 576dots, 512dots, 436dots, 432dots,
420dots, 384dots, 360dots, 390dots, 546dots,
390dots, 546dots
MSW8-2
Paper Type
1 Color
Normal
1 Color Normal, 2 Color Normal
MSW9-1
Code Page
PC 437
PC 437, Katakana, PC 850,858, PC 860, PC 863,
PC 865, PC 852, PC 866, PC 857, WPC1252,
Space page, PC 864, Thai Code 18
MSW9-2
Int’Char Set
USA
USA, France, Germany, England, Denmark,
Sweden, Italy, Spain, Japan, Norway, Denmark 2,
Spain 2, Latin America, Korea, Croatia, China
MSW9-3
Kanji
OFF
ON, OFF
MSW9-4
JIS/Shift JIS
JIS
JIS, Shift JIS
MSW10-1
Print Density
100 %
70 %, 75 %, 80 %, 85 %, 90 %, 95 %, 100 %, 105 %,
110 %, 115 %, 120 %, 125 %, 130 %, 135 %, 140 %
MSW10-2
Print Speed
Level 9
Level 1, Level 2, Level 3, Level 4, Level 5, Level 6,
Level 7, Level 8, Level 9
MSW10-3
ACK Timing
Before Busy Before Busy, Same Period, After Busy
MSW10-4
Reserved
MSW10-5
Reserved
MSW10-6
Buzzer Sound
Tone 2
Tone 1, Tone 2, Tone 3, Tone 4
Switch no.
Function
OFF