beautypg.com

Off-season storage, Trouble shooting guide – MTD 630 thru 635 User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

OFF-SEASON STORAGE

If the log splitter will not be used for a period longer

than 30 days, the following steps should be taken to

prepare the log splitter for storage.

1. Clean the engine and the entire log splitter thor­

oughly.

2. Refer to the engine manual for correct engine

storage instructions. Follow instructions care­

fully.

3. Wipe unit with an oiled rag to prevent rust, espe­

cially wedge and beam.

NOTE: When storing any type of power equipment in
an unventilated or metal storage shed, care should be

taken to rustproof the equipment by coating with a

light oil or silicone.

4. The tongue can be removed and reattached in an

upright position as shown in figure 17 to take less
space when storing.

5. Store unit in a clean, dry area. Do not store next

to corrosive materials, such as fertilizer.

FIGURE 17.

TROUBLE SHOOTING GUIDE

Trouble

Possible Cause(s)

Corrective Action

Engine fails to start

1. Fuel tank empty, or stale fuel.

2. Blocked fuel line.

3.

Spark plug wire disconnected.

4. Faulty spark plug.

1., Fill tank with clean, fresh gasoline.

2. Clean fuel line.

3.

Connect wire to spark plug.

4. Clean, adjust gap or replace.

Engine runs erratic

1

. Unit running on CHOKE-

2. Spark plug wire loose.

3.

Blocked fuel line or stale fuel.

4. Water or dirt in fuel system.

5. Dirty air cleaner.

6.

Carburetor out of adjustment.

1. Move choke lever to OFF position.

2. Connect and tighten spark plug

wire.

3.

Clean fuel line; fill tank with clean

fresh gasoline.

4. Drain fuel tank. Refill with fresh

fuel.

5. Clean air cleaner.!

6.

Adjust carburetor.!

Engine overheats

1. Engine oil level low.
2. Air flow restricted.

3.

Carburetor not adjusted properly.

1. Fill crankcase with proper oil.

2. Remove blower housing and

clean.!

3.

Adjust carburetor.!

Will not split logs

Reservoir fluid level low.

Check and fill reservoir tank as
instructed in Operation section
of this manual.

Leaking cylinder

1. Broken seals.

2

. Scored cylinder.

1. Replace seals.*

2. Replace cylinder.*

NOTE: For repairs beyond the minor adjustments iisted above, piease contact your nearest authorized service dealer.

*Should be performed by an authorized service dealer only,
t Refer to separate engine manual packed with your log splitter.

13