beautypg.com

Esc bel n1 n2 – Citizen Systems iDP-3423 User Manual

Page 93

background image

iDP-3420/3421/3423 User’s Manual

93

CITIZEN

ESC BEL n1 n2

[Function]

Setting the external device drive pulse width

[Code]

<1B>H <07>H n1 n2

[Range]

1 £ n1 £ 127
1 £ n2 £ 127

[Outline]

This command sets the power-on time to drive an external device(Cash drawer).
Power-on time = n1 ´ 10 (ms)
Delay time = n2 ´ 10 (ms)
To actually drive the drawer, use the and commands.

[Default]

n1 = n2 = 20 (200ms)

BEL

[Function]

Driving command A for drawing-1

[Code]

<07>H

[Outline]

This command drives the drawer connector no. 2 pin under the condition set with
the n1 n2 command. This command is executed in order of entry
into the input buffer.