3-20

Switch Hardware

The alarm relay contacts are normally closed when there is no power to the
switch. The user can attach alarm circuits to these contacts to trigger an exter-
nal alarm in the case of an alarm condition on the switch.

The user can define AL1 and AL2 as major and minor alarm indicators and
can display which condition is alarming through the use of AMI. For more
information, please refer to the alarm configuration section in Appendix B,
AMI Configuration Commands, in the Cabletron ATM Switch Configuration
Manual.

Table 3.7 -

Alarm Relay Contact Status During Major and Minor Alarms

NOTE:

In Table 1.7, “Jumped” indicates that the cir-
cuit between the indicated pins has been
closed (i.e., an external alarm would be trig-
gered if connected to the pins).

Condition

Pins 1 and 2

Pins 3 and 4

Switch Powered OFF

Jumped

Jumped

During Boot

Indeterminate

Indeterminate

Normal Operation

Open

Open

Minor Alarm Only

Jumped

Open

Major Alarm Only

Open

Jumped

Major and Minor Alarms

Jumped

Jumped