1. POWER
: Switches power on to the unit.
Each time you turn on the deck, the last on/off status
of the ADJUST switch (122 MKIII only) and Auto
Reverse (CID / ZZD ) switch (112R MKII only) and
the
last
play/record
direction
as
set
with
the
DIRECTION switch (112R MKII only) are retrieved from
a backup memory.
2. EJECT
: Opens the cassette compartment.
3. PITCH CONT
: Provides about a plus or minus 12
%
variation to the tape speed in both Play and Record modes.
Unless you use the function intentionally, make sure that
the knob is at its OFF position for the tape to roll at
normal speed (1-7/8 i.p.s. or 4.8 cm/sec.).
4. REW
: Winds the tape at high speed in reverse. If
pressed during Play Pause, enables reverse cueing.
5. F.FWD
: Winds the tape at high speed in the forward
direction. If pressed during Play Pause, enables the forward
6. STOP :
Stops all tape motion.
7.
PLAY
: Starts playback. If pressed together with
RECORD, starts recording. If pressed during Record Pause,
resumes recording.
8. PAUSE
: Temporarily stops play or recording ; to
resume the function interrupted, press PLAY. If pressed
together with RECORD, activates Record Ready mode,
allowing you to start recording by pressing PLAY only.
9. RECORD
: Starts recording when pressed together with
PLAY.
10. Tape Counter
: Displays the distance from a zero
reference point, selected by pressing RESET (-99 M 59 S
to 99 M 59 S with the 122 MKIII and 112R MKII; or 00
00 to 99 99 with the 112 MKII).
A
type of tape
in use (NORMAL, Cr02 or METAL) is
indicated on the right hand side of the tape counter, and the
monitor source
too—"INPUT" lights unless tape signal is
feeding the front PHONES and rear OUTPUT.
NOTE
122 MKIII and 112R MKII ; The tape counter is not a
clock. Its reading depends on the tape length, relative
tape packs on both reels and other mechanical
factors. Use a watch to measure the correct length of
particular program.
Discrepancy between measurements on the tape
counter and a clock (from beginning to end, one-way
run):
Normal/Cr02
Metal
C-30
+3 min. 00 sec. to
4 min. 00 sec.
—
C-46
+1 min.30 sec. to
2 min.45 sec.
+2 min.OO sec.to
3 min.15 sec.
C-60
-45 sec. to +30 sec.
0 min.OO sec. to
+1 min.15 sec.
C-90
-1 min.30 sec. to
-30 sec.
-1 min.15 sec. to
0 min. 00 sec.
C-30/46 measurements made with narrow hub cassettes.
11. INPUTS, L and R
: Allow individual control of both
channel levels.
122 MKIII : Both controls are geared together to allow
simultaneous adjustment of the record level of both
channels. Each channel can be adjusted independently by
holding one knob and turning the other.
12. VU meters
: indicate input or tape signal levels
depending on the transport mode and the MONITOR switch
setting.
13.
MONITOR
: Setting to INPUT routes the input
signal to the PHONES and OUTPUT Jacks, whatever the
transport mode. If set to AUTO, the input signal can be
monitored in Record Pause (Ready) mode, and the tape
signal while recording (off-tape monitoring) or playing.
The VU meters also switch the same way.
The 112 MKII does not provide off-tape monitoring ; you'll
hear the input signal instead while recording is taking place.
14.
OUTPUT
: Adjusts the signal level sent to the
OUTPUT Jacks on the rear panel.