NOTE: No choke 1$ roc|ui№d on waiTn engines. Mtdte
sure choke
1$
in the *N0
CHOKE
^ position on warm
engine etarta.
iVCAUTlON
I
You MUST ufq>kig any load
from the generator before
starting to prevent permanent damage to any
appliances.
For electric start;
- Place OFF^UN/ST
af
TT switch in the START
position.
NOTE; When the engine starts the switch will
remain in the RUN position.
For recoil start:
• Place OFF/RUN/STAHT switch in the RUN posU
tion.
•
Grasp handle on rope starter and pull slowly until
resistance is felt. Let the nope rewind
slowly.
Pull
rope with a rapid full arm stroke. Let rope rewind
slowly. Repeat if necessary.
NOTE: IF ENGINE OIL LEVEL IS TOO LOW, EN
GINE WILL NOT STMTT. CHECK OIL LEVEL AND
ADD IP NECESSARY.
•
When engine warms up, gradually push choke
control In to the NO CHOKE position.
IMPORTANT: Allow generator to run at no load
for 5 minutes upon each initial start-up to allow
engine and generator to stabilize.
STOPPINO ENOINE
•
Disconnect all electrical toads.
•
Him OFF/RUN/START awitoh to ’OFF* position.
Close fuel shut-off valve.
NMPORTANIi Never stora engine with fuel in tank,
indoors, or in enclosed, poorly ventilated ereas or
where fuel fumes may reeich an open flame.
CONNECTING ELECTRICAL LOADS
•
Let engine run and warm up for five minutes after
starring with no elactrical toad.
Connect load« in the foltowing manner to prevent
damege to equipment
•
Connect inductive load equipment first, inductive
loads consist of refrigerators, freezers, water
pumps, air oonditioriers, or small hand tools.
Connect the items that require the most wattage
first.
•
Connect the lights next.
> Voltage sensitive equipment should be the last
equipment oorviected to the generator. Plug
voltage sensitive appliances such at TV's, VCR's,
microwaves, ovens, oorrtputsrs, and cordless
Telephones into a UL Nsted voltage surge protec
tor, then connect the UL listed voltage surge
proteetor to the generator.
IMPORTANT; You should always add up the rated
watts of all lights, tools and applianoes you are
powering at one time. This total should not
exceed the rated capacity of you generator or
otrcuit breaker rating of the reeeptaole supplying
power.